Starting up the device – Basic configuration
Leuze electronic
IPS 208i
39
8.3
Configuring and aligning the device via control buttons
Prerequisites:
• The positioning sensor is correctly mounted; in particular, at the correct working distance (see chapter
• The positioning sensor is correctly connected (see chapter 7 "Electrical connection").
• The application data is set via the webConfig tool (see chapter 9 "Commissioning – Leuze electronic
• The housing hood of the positioning sensor is aligned parallel to the marker.
• The marker is as close as possible to the center of the positioning sensor's region of interest.
NOTICE
The working distance set in the device must correspond to the actual working distance.
NOTICE
Ä
Use the navigation button
to move through the menu.
Ä
Activate or deactivate the desired selection with the enter button
.
Ä
First, the program is selected and confirmed. The
AUTO
or
ADJ
function is then activated or
deactivated.
Ä
Press the navigation button
once.
ð
The PROGRAM 1 LED flashes; program 1 is preselected.
ð
Press the navigation button several times to preselect the desired program.
Ä
Press the enter button
to activate the desired program.
Ä
Press the navigation button
repeatedly until the AUTO LED flashes.
Ä
Press the enter button
to activate the
AUTO
function.
Ä
Align the positioning sensor so that all four feedback LEDs permanently illuminate green.
NOTICE
The feedback LEDs signal the X/Y distance to the marker by means of the flashing frequency:
Ä
Slow flashing: Large distance
Ä
Fast flashing: Short distance
Ä
Continuous illumination: Positioning sensor is optimally aligned
Ä
If all four feedback LEDs illuminate green continuously, press the enter button
once.
ð
The positioning sensor is optimally aligned.
ð
The exposure time and the marker diameter are taught.
ð
The position is taught if the entire region of interest is still in the field of view after teaching-in.
NOTICE