Function largely independent of surface 
properties, ideal for detection of liquids, 
bulk materials, transparent media, …

Sound exit less than 90° to the longitudinal 
axis

Small dead zone at long scanning range

1 analog output 0 … 10V or 4 … 20mA

1 switching output (PNP or NPN)

NO/NC function reversible

NEW

 – Both outputs can easily be taught 

using a button

NEW

 – Stable plastic design

NEW

 – Temperature-compensated 

scanning range

50 … 400mm

150 … 1600mm

10 - 30 V

DC

4...20 mA

0...10 V

Accessories:

(available separately)

Mounting systems

Mounting adapter M18-M30: 
BTX-D18M-D30 (Part no. 50125860)

Cables with M12 connector
(KD …)

IP 67

IEC 60947...

IEC 60947...

Dimensioned drawing

A

Active sensor surface

B

Teach-in button

C

Indicator diodes

Electrical connection

DMU318…W

90° angled ultrasonic sensors with analog and switching output

 DMU318-400.W…-M12 - 01

DMU318-1600.W…-M12 - 01

en

01

-2

01

7/

02

5

01

358

24

Содержание DMU318 W Series

Страница 1: ...PN NO NC function reversible NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 50 400mm 150 1600mm 10 30 V DC 4 20mA 0 10V Acces...

Страница 2: ...utton 12s Indicators Yellow LED OUT2 object detected Blue LED Analog OUT object detected Yellow green or blue green LED flashing Teach in teaching error Green LED Object within the scanning range Mech...

Страница 3: ...contact preset C Analog output 4 20mA V Analog output 0 10V Pin assignment of connector pin 5 gray cable wire Sync MUX K Synchronization multiplex input Connection technology M12 M12 connector 5 pin...

Страница 4: ...rmally closed Close Far Far Close Dead zone Sensor OUT1 active Yellow LED ON Green LED OFF OUT1 not active Yellow LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT1 not activ...

Страница 5: ...th 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the ou...

Страница 6: ...output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 Changeover of the switching function 1 To change the switching function of output O...

Страница 7: ...that is to be taught OUT1 or Analog OUT 1 Press the teach button for 2s to activate teach mode The yellow LED OUT 1 flashes at 1Hz While in this state output OUT 1 can be taught 2 To teach output Ana...

Страница 8: ...ning range of 400mm 90mm scanning range of 1600mm 310mm 2 To adjust analog output Analog OUT press the teach button for 2 7s until the blue and green LEDs flash simultaneously at 3Hz 3 Release the but...

Страница 9: ...of the same type are wired together in a network according to the following diagram The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual...

Страница 10: ...factory setting 1 switching point at 400mm or 1600mm rising characteristic curve with spread over the entire scanning range Resetting to factory settings 1 When switching on the supply voltage during...

Отзывы: