Technical data
Leuze electronic
DCR 202i
59
Table 14.4:
Environmental data
14.2 Optical data
14.2.1 Reading performance
Ambient temp. (operation/storage)
0 °C … +50 °C/-20 °C … +70 °C
Air humidity
Max. 90% rel. humidity, non-condensing
Ambient light
Max. 2000 Lux
Electromagnetic compatibility
EN 61000-6-2, EN 61000-6-4
Vibration
IEC 60068-2-6, test Fc
Continuous shock
IEC 60068-2-29, test Eb
Certifications
UL 60950-1
CAN/CSA C22.2 No. 60950-1-07
CSA C22.2 No. 60950-1-07
Conformity
CE, FCC, UL
Integrated LED illumination
Red light (visible, 616 nm)
Risk group 0 (exempt group)
Acc. to IEC 60825-1, EN 62471:2008
Integrated feedback LED
Green (528 nm)
Beam exit
Front
Image sensor
Global shutter CMOS Imager
Number of pixels
1280 x 960 pixels
Optics models
Resolution
• High Density (N)
0.127 mm (5 mil) … 0.25 mm (10 mil)
• Medium Density (M)
0.19 mm (7.5 mil) … 0.33 mm (13 mil)
• Low Density (F)
0.25 mm (10 mil) … 0.5 mm (20 mil)
Electronic shutter speeds
68 µs … 5 ms (flash)
Read fields
• N-optics: 40 mm … 90 mm at m=0.19 mm (7,5 mil)
• M-optics: 60 mm … 150 mm at m=0.25 mm (10 mil)
• F-optics: 80 mm … 300 mm at m=0.33 mm (13 mil)
Reading distance
see chapter 6.1.3 "Determining the reading distance"
Object speed
• N-optics: Up to 4 ms at m=0.19 mm (7.5 mil)
• M-optics: Up to 5 ms at m=0.25 mm (10 mil)
• F-optics: Up to 6 ms at m=0.33 mm (13 mil)