Mounting
Leuze electronic
DCR 202i
22
Recommended tilt angle or angle of inclination: 10° … 20°
1
Code label
2
Mounting with tilt angle
3
Mounting with angle of inclination
Figure 6.1: Mounting with tilt angle or angle of inclination
6.1.3 Determining the reading distance
In general, the read field of the code reader becomes larger with increasing reading distance. This also
results in a decrease in the resolution, however.
The following figures show typical reading distances for the individual optics models of the code reader.
For the relationship between camera distance and read field see figure 6.6.
Reading distances for code readers with N-optics
1
Reading distance [mm]
Figure 6.2: Typical reading distances for 1D- and 2D-codes with various modulus sizes of the codes
10° … 20°
10° … 20°
1
2
3
1
Code reading while in motion is dependent on the code type, code size, cell or modulus size of
the code and the position of the code in the read field of the code reader.
Please note that the actual reading distances are also influenced by factors such as labeling
material, printing quality, reading angle, printing contrast etc., and may thus deviate from the
reading distances specified here.
1D-Codes
2D-Codes
400
[mm]
350
300
250
200
150
100
50
0
0.127 mm (5 mil)
0.19 mm (7.5mil)
0.25 mm (10 mil)
0.5 mm (20 mil)
0.127 mm (5 mil)
0.19 mm (7.5 mil)
0.25 mm (10 mil)
0.5 mm (20 mil)