Starting up the CSL 710 with IO-Link interface
Leuze electronic
CSL 710
63
Configuration for block evaluation of beam areas (group 9)
In this group, a detailed area configuration can be displayed and a beam area configured for the
block evaluation.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Teach height area
75
0
unsigned 8
RW
0 … 7
0
Active: all beams free
Not active: at least one beam interrupted
1: Area 1
…
8: Area 8
Display detailed area
configuration
77
0
unsigned 8
WO
1 … 8
Select the desired area (1 … 8) for which the con
-
figuration is to be edited in detail.
0: Area 01
1: Area 02
2: Area 03
…
7: Area 08
Configuration of area 1
Configuration of area 01
90
1
record
112 bit, iso
-
lated access
to sub-index
not possible
RW
Configuration of the area: definition of the status
conditions so that the area takes on a logical 1 or 0.
For diagonal- or crossed-beam mode, the numbers
of the logical beams are to be entered.
Area
90
1
(bit
offset
= 104)
unsigned 8
RW
0 … 1
0
0: Not active
1: Active
Active beam
90
1
(bit
offset
= 96)
unsigned 8
RW
0 … 1
0
0: Light switching (beam is active if light path is
free)
1: Dark switching (beam is active if light path is
interrupted)
Start beam of the area
90
1
(bit
offset
= 80)
unsigned 8
RW
1 … 1774
1
End beam of the area
90
1
(bit
offset
= 64)
unsigned 8
RW
1 … 1774
1
Number of active beams
for area ON
90
1
(bit
offset
= 48)
unsigned 16
RW
0 … 1774
0
Number of active beams
for area OFF
90
1
(bit
offset
= 32)
unsigned 16
RW
0 … 1774
0
......
....
....
..
..
..
.......
......
....
....
..
..
..
.......
Configuration of area 08
Configuration of area 08
97
8
record
112 bit, iso
-
lated access
to sub-index
not possible
RW
Configuration of the area: definition of the status
conditions so that the area takes on a logical 1 or 0.
For diagonal- or crossed-beam mode, the numbers
of the logical beams are to be entered.
Area
97
8
(bit
offset
= 104)
unsigned 8
RW
0 … 1
0
0: Not active
1: Active
Active beam
97
8
(bit
offset
= 96)
unsigned 8
RW
0 … 1
0
0: Light switching (beam is active if light path is
free)
1: Dark switching (beam is active if light path is
interrupted)