Leuze electronic
BCL 558
i
87
TNT
35/7-2
4
V
Status display of the USB interface
USB
The BCL 558
i
is connected to a PC via the USB interface.
MS
An external parameter memory is properly connected to the USB interface of the
BCL 558
i
.
Read result
The read bar code information is displayed.
EtherNet/IP status
ENIP
EtherNet/IP interface is activated.
8.2.2
LED status indicators
PWR LED
off
Device OFF
- no supply voltage
flashes green
Device ok, initialization phase
- no bar code reading possible
- voltage connected
- self test running
- initialization running
green continuous light Device ok
- bar code reading possible
- self test successfully finished
- device monitoring active
orange continuous light Service mode
- bar code reading possible
- configuration via the USB service interface
- configuration via the display
- no data on the host interface
flashes red
Device ok, warning set
- bar code reading possible
- temporary operating fault
red continuous light
Device error / parameter enable
- no bar code reading possible