Specifications
44
BCL 504
i
Leuze electronic
5.6.1
High Density (N) Optics: BCL 504
i
SN 100/102
Figure 5.6:
"High Density" reading field curve for line scanner (with/without
deflection mirror)
The reading field curve applies for the reading conditions stated in table 5.8.
0
-100
200
100
300
400
500
600
700
800
900
1000
100
200
300
400
-100
-200
-300
-400
BCL 500/501/504/508
i
SN 100/102
m = 0,25
m = 0,3
m = 0,35
m = 0,5
m = 0,35
m = 0,3
m = 0,25
m = 0,5
Read distance [mm]
Reading field width [mm]