Commissioning and configuration
Leuze electronic
BCL 504
i
167
TNT 35/7-24V
Input data length
2 bytes
Output data
Switching output 3
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several
times" was configured as com-
parison mode, this bit is toggled
each time the event counter is
exceeded.
The bit is reset to the init. value
by resetting the event counter.
1.5
Bit
0
→
1: Event
counter
exceeded
1
→
0: Event
counter
exceeded
again
0
-
Comparison state
switching output 4
(Event Counter)
Indicates whether the event
counter has exceeded the set
comparative value.
The bit is reset to the init. value
by resetting the event counter.
1.6
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 4
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several
times" was configured as com-
parison mode, this bit is toggled
each time the event counter is
exceeded.
The bit is reset to the init. value
by resetting the event counter.
1.7
Bit
0
→
1: Event
counter
exceeded
1
→
0: Event
counter
exceeded
again
0
-
Output data
Description
Addr.
Data type
Value range
Init
value
Unit
Switching output 1
Sets the state of switching out-
put 1
0.0
Bit
0: Switching output
0
1: Switching output
1
0
-
Switching output 2
Sets the state of switching out-
put 2
0.1
Bit
0: Switching output
0
1: Switching output
1
0
-
Switching output 3
Sets the state of switching out-
put 3
0.2
Bit
0: Switching output
0
1: Switching output
1
0
-
Switching output 4
Sets the state of switching out-
put 4
0.3
Bit
0: Switching output
0
1: Switching output
1
0
-
Reset Event
Counter
Switching output 1
Sets the event counter of the
activation function [AF] for
switching output 1 back to
zero.
0.4
Bit
0 -> 1: Perform
reset
1 -> 0: No function
0
-
Reset Event
Counter
Switching output 2
Sets the event counter of the
activation function [AF] for
switching output 2 back to
zero.
0.5
Bit
0 -> 1: Perform
reset
1 -> 0: No function
0
-
Table 10.53:
Output data for module 74 Input/output status and control
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Table 10.52: