Commissioning and configuration
Leuze electronic
BCL 504
i
155
TNT 35/7-24V
10.12.2 Parameters for operating as an input
Debounce time
Parameter for setting the software debounce time for the switching input. The definition of a
debounce time extends the signal transition time accordingly.
If the value of this parameter = 0, no debouncing takes place; otherwise, the configured
value represents the duration in milliseconds for which the input signal must be present and
stable.
Start-up delay td_on
If the value of this parameter = 0, no start-up delay occurs for the activation of the input func-
tion; otherwise, the configured value represents the time in milliseconds by which the input
signal is delayed.
Figure 10.5: Start-up delay in input mode
Input signal
Output signal
Start-up delay td_on
Switch-on time ton
Switch-off delay td_off