Commissioning and configuration
134
BCL 504
i
Leuze electronic
10.8.10 Module 37 – Decoding quality
Description
The module defines input data for the communication of the calculated decoding quality of
the currently transmitted barcode.
Parameters
None
Input data
Input data length
1 byte consistent
Output data
None
10.8.11 Module 38 – Code direction
Description
The module defines input data for the communication of the detected code direction of the
currently transmitted barcode.
Parameters
None
Input data
Input data length
1 byte
Output data
None
Comment:
A decoding result of type "No Read" has as code direction the value 2 = unknown!
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Decoding quality
Decoding quality of the transmit-
ted barcode
0
UNSIGNED8
0 … 100
0
1%
Table 10.27:
Input data for module 37
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Code direction
Code direction of the transmitted
barcode
0
UNSIGNED8
0: Normal
1: Inverted
2: Unknown
0
-
Table 10.28:
Input data for module 38