Commissioning and configuration
Leuze electronic
BCL 504
i
133
TNT 35/7-24V
10.8.8
Module 35 – Barcode length
Description
The module defines the input data for the communication of the length of the currently output
barcode.
Parameters
None
Input data
Input data length
2 byte consistent
Output data
None
10.8.9
Module 36 – Scans with information
Description
The module defines input data for the communication of the calculated number of scans
which provided information contributing to the result of the barcode.
Parameters
None
Input data
Input data length
2 byte consistent
Output data
None
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Barcode length
Length/duration of the currently
output barcode, beginning with
the code position specified in
module 35 in 1/10 degrees.
0 … 1
UNSIGNED16
1 … 900
1
1/10
degree
Table 10.25:
Input data for module 35
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Scans with information per
barcode
See above
0 … 1
UNSIGNED16
0 … 65535
0
-
Table 10.26:
Input data for module 36