Electrical connection
Leuze electronic
BCL 608i
30
7.3
SERVICE – USB interface (type A)
Figure 7.5: Service, USB, type A
Table 7.2:
Pin assignments of SERVICE – USB interface
7.4
SW IN/OUT – Switching input/switching output
Figure 7.6: SW IN/OUT, M12 socket (A-coded)
Table 7.3:
Pin assignment SW IN/OUT
4
3
1
2
Pin
Name
Comment
1
VB
Positive supply v5 V DC
2
D-
Data -
3
D+
Data -
4
GND
Ground
NOTICE
Maximum load of the +5 V DC supply voltage of the USB interface is 200 mA!
Ensure adequate shielding.
The entire interconnection cable must absolutely be shielded acc. to the USB specifications. Cable
length must not exceed 3 m.
Use the Leuze-specific USB service cable (see chapter 16 "Ordering information and accessories") for
the connection and use a service PC to configure.
NOTICE
IP 65 is achieved only if the connectors and caps are screwed into place. Alternatively, a parameter
memory in the form of a USB memory stick certified by Leuze electronic GmbH + Co. can be connected
to the provided USB service interface. With this Leuze memory stick, degree of protection IP 65 is also
ensured.
1
3
2
4
5
FE
Pin
Name
Comment
1
VOUT
Voltage supply for sensors
(VOUT identical to VIN at PWR IN)
2
SWIO_
1
Configurable switching input / output 1
3
GND
GND for the sensors