Voltage supply
In the connector unit MA 2, the connections for the voltage supply are implemented twice.
This permits wiring through or the voltage supply of additional components.
Table 6.4:
Terminal assignment voltage supply
Notice!
It is imperative that the protective conductor PE also is wired through to avoid electromag-
netic interference.
Switching inputs 1 and 2
The MA 2 connector unit is equipped with two switching inputs SE 1 and SE 2 (SE 2 can
only be activated with BCL 22).
• Input voltage: 12 … 30VDC
Table 6.5:
Terminal assignment switching inputs
Switching outputs 1 and 2
The MA 2 is equipped with 2 switching outputs SA1 and SA2 (SA 2 can only be activated
with BCL 22) which can be programmed for various switching functions using the
"BCLConfig" software.
• Output voltage corresponds to operating voltage
• Output current: I
max
= 100mA
The switching voltage for the output is generated by the operating voltage V_IN:
• VDD_SA = VDD_IN
• GND_SA = GND_IN
Table 6.6:
Terminal assignment switching outputs
Terminal
Signal
Function
17
V_IN
Operating voltage 10 … 30VDC
18
V_IN
Operating voltage 10 … 30VDC
19
GND_IN
Operating voltage 0VDC
20
GND_IN
Operating voltage 0VDC
21
PE
Protective earth, grounding
22
PE
Protective earth, grounding
Terminal
Signal
Function
7
SE2
Switching input 2, 12 … 30VDC
9
SE1
Switching input 1, 12 … 30VDC
11
VDD_SE
Supply voltage, switching input,
equal to V_IN device
12
GND_SE
Supply voltage, switching input,
equal to GND_IN device
Terminal
Signal
Function
13
SA2
Switching output 2
14
SA1
Switching output 1
16
GND_SA
External supply voltage for switching output 0VDC