![Leuze electronic AMS 384 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/leuze-electronic/ams-384/ams-384_technical-description_1883976014.webp)
Specifications
11
AMS 384
i
Leuze electronic
4
Specifications
4.1
Specifications of the laser measurement system
4.1.1
General specificationsAMS 384
i
Measurement data
AMS 384
i
40 (H) AMS 384
i
120 (H) AMS 384
i
200 (H) AMS 384
i
300 (H)
Measurement range
0.2 … 40 m
0.2 … 120 m
0.2 … 200 m
0.2 … 300 m
Accuracy
± 2 mm
± 2 mm
± 3 mm
± 5 mm
Consistency
1)
0.3 mm
0.5 mm
0.7 mm
1.0 mm
Light spot diameter
≤
40 mm
≤
100 mm
≤
150 mm
≤
225 mm
Measurement value output
1,7 ms
Integration time
8 ms
Resolution
adjustable, see chapter of the individual interfaces
Temperature drift
≤
0.1 mm/K
Ambient temperature sensitivity
1 ppm/K
Air pressure sensitivity
0.3 ppm/hPa
Traverse rate
≤
10 m/s
Electrical data
Supply voltage Vin
2)
18 … 30 V DC
Current consumption
without device heating:
≤
250 mA / 24 V DC
with device heating:
≤
500 mA / 24 V DC
Optical data
Transmitter
laser diode, red light, wavelength 650 … 690 nm
Laser class
2 acc. to EN 60825-1, CDRH
Laser life expectancy
3)
average temperature / year
50 °C: 23.000 h
25 °C: 60.000 h
20 °C: 75.000 h
10 °C: 120.000 h
Interfaces
InterBus remote bus
500 kbit/s / 2 Mbit/s
Operating and display elements
Keyboard
4 buttons
Display
monochromatic graphical display, 128 x 64 pixels
LED
2 LEDs, two-colored
Inputs/outputs
Quantity
Input
Output
2, programmable
protected against polarity reversal
max. 60 mA, short-circuit proof