PROFINET interface
Leuze electronic
AMS 348
i
62
TNT
35/7-2
4
V
Figure 9.15: Linking of the device name to the MAC ID of the participant
The same configuration mask can be used, if necessary, to manually assign an IP address.
Alternatively, the IP address can be assigned via a DHCP server.
9.9
PROFINET GSD file
9.9.1
General information on the GSD file
The functionality of the AMS 348
i
is defined via an XML-based GSD file. The GSD file is the
same for all AMS 348
i
and forms a mandatory part of the device. The GSD file has a modular
architecture and contains all the functions of the AMS 348
i
in modules.
The AMS 348
i
offers 17 different modules. Each of these modules can only be activated
once per AMS.
The AMS 348
i
checks its max. permissible number of modules. The control also reports an
error if the input and output data across all modules exceed a total length of 1024 bytes.
The specific limits of the individual modules of the AMS 348
i
are stored in the module
description and in the GSD file.