PROFINET interface
59
AMS 348
i
Leuze electronic
9.8.4.10 Step 4 – Transfer of the configuration to the IO Controller (S7 PLC)
After the correct transfer to the IO Controller (S7 PLC), the PLC automatically carries out
the following activities:
• Check device names
• Assignment of the IP addresses that were configured in the HW Config to the
IO devices
• Establishment of a connection between the IO Controller and configured IO devices
• Cyclical data exchange
Notice!
Participants without assigned device names cannot yet be addressed at this point in time!
9.8.4.11 Step 5 – Configuration of the device name - naming the device
Each AMS 348
i
has an individual and unique MAC ID. The MAC ID can be found on the name
plate of the device.
Figure 9.12: MAC ID on the name plate
Notice!
This figure is for illustration only and does not correspond in all details to the AMS 348
i
. The
MAC ID in particular must be read separately from each individual device. The MAC ID is
also shown in the display of the AMS 348
i
.
Network information
IP Address:
---.---.---.---
Netzmask:
---.---.---.---
Gateway:
---.---.---.---
MAC ID:
--.--.--.--.--.--
DevName:
-------------------------
After successful naming, the device name can be read here under
DEVName
.