Display and control panel AMS 307i
46
AMS 307
i
Leuze electronic
I/O submenu
Error delay
ON / OFF
Specifies whether, in the event of an error, the position value immediately
outputs the value of the "Position value in the case of error" parameter
or the last valid position value for the configured error delay time.
ON/100 ms
Position value in
the case of error
Last valid value / zero
Specifies which position value is output after the error delay time elapses.
Zero
Table 8.4:
I/O submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
I/O 1
Port config-
uration
Input/Output
Defines whether I/O 1 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
No function
Activation
Low active/High active
Low active
Switching
output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching out-
put.
Plausibility (PLB),
hardware (ERR)
Activation
Low active/High active
Low active
I/O 2
Port config-
uration
Input/Output
Defines whether I/O 2 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
No function
Activation
Low active/High active
Low active
Switching
output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) /
Temp. (TMP) / Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected switching out-
put.
Intensity (ATT),
Temp. (TMP),
Laser (LSR)
Activation
Low active/High active
Low active
Limit values
Upper pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Upper pos.
limit 2
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 2
Activation
ON / OFF
OFF
Table 8.3:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard