AMS 307i
Optical Laser Measurement System – SSI
de
01-2017/09
5013
7614
We
res
er
ve the r
ight to
ma
ke tec
hnica
l cha
nges
O r i g i n a l o p e r a t i n g i n s t r u c t i o n s
Страница 1: ...AMS 307i Optical Laser Measurement System SSI de 01 2017 09 50137614 We reserve the right to make technical changes Original operating instructions ...
Страница 2: ...Leuze electronic AMS 307i 2017 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze com ...
Страница 3: ...splay See Indicators in the display on page 39 Parameter Parameter handling SSI Position value I O Other Parameter main menu ConfigurationoftheSSIinterfaceisperformedviathe SSI menu item Language selection o Deutsch English o Español o Français o Italiano Language selection main menu Selection of the display language See Language selection menu on page 48 Input of values 100 0123456789 save Standa...
Страница 4: ... 4 Technical data 13 4 1 Specifications of the laser measurement system 13 4 1 1 General specifications AMS 307i 13 4 1 2 Dimensioned drawing AMS 307i 15 4 1 3 Type overview AMS 307i 16 5 Installation and mounting 17 5 1 Storage transportation 17 5 2 Mounting the AMS 307i 18 5 2 1 Optional mounting bracket 20 5 2 2 Parallel mounting of the AMS 307i 21 5 2 3 Parallel mounting of AMS 307i and DDLS o...
Страница 5: ... reflector 32 6 4 3 Table of reflector pitches 35 7 Electrical connection 36 7 1 Safety notices for the electrical connection 36 7 2 PWR voltage supply switching input output 37 7 3 SSI 37 7 4 Service 38 8 Display and control panel AMS 307i 39 8 1 Structure of the control panel 39 8 2 Status display and operation 39 8 2 1 Indicators in the display 39 8 2 2 LED status displays 41 8 2 3 Control butt...
Страница 6: ...0 3 Interface errors 58 10 3 1 BUS LED 58 10 4 Status display in the display of the AMS 307i 59 11 Type overview and accessories 60 11 1 Part number code 60 11 2 Type overview AMS 307i SSI 60 11 3 Overview of reflector types 60 11 4 Accessories 61 11 4 1 Accessory mounting bracket 61 11 4 2 Accessory deflector unit 61 11 4 3 Accessory M12 connector 61 11 4 4 Accessory ready made cables for voltage...
Страница 7: ...icates text passages containing important information 1 2 Declaration of conformity The AMS 307i absolute measuring optical laser measurement system was designed and manufactured in accordance with applicable European directives and standards The AMS series is UL LISTED according to American and Canadian safety standards and fulfills the requirements of Underwriter Laboratories Inc UL Notice The D...
Страница 8: ...the receiving element of the laser measurement system The AMS 307i uses the propagation time of the light to calculate the distance to the reflector The high absolute measurement accuracy of the laser measurement system and the fast response time are designed for position control applications With the AMS 3xxi product series Leuze electronic makes available a range of internation ally relevant int...
Страница 9: ...and their trolleys Elevators Electroplating plants Attention For UL applications use is permitted exclusively in Class 2 circuits according to NEC National Electric Code CAUTION Observe intended use Only operate the device in accordance with its intended use The protection of per sonnel and the device cannot be guaranteed if the device is operated in a manner not complying with its intended use Le...
Страница 10: ... device Certified electricians Electrical work must be carried out by a certified electrician Due to their technical training knowledge and experience as well as their familiarity with relevant standards and regulations certified electricians are able to perform work on elec trical systems and independently detect possible dangers In Germany certified electricians must fulfill the requirements of ...
Страница 11: ...ok directly into the laser beam or in the direction of reflecting laser beams If you look into the beam path over a longer time period there is a risk of injury to the retina Do not point the laser beam of the device at persons Interrupt the laser beam using a non transparent non reflective object if the laser beam is accidentally directed towards a person When mounting and aligning the device avo...
Страница 12: ...iate for the place of use When using the device in the U S A use the stick on label with the Complies with 21 CFR 1040 10 notice Affix the laser information and warning signs near the device if no signs are attached to the device e g because the device is too small or if the attached laser information and warning signs are concealed due to the installation position Affix the laser information and ...
Страница 13: ...se duration Wavelength RAYONNEMENT LASER NE PAS REGARDER DANS LE FAISCEAU APPAREIL À LASER DE CLASSE 2 EN 60825 1 2007 Puissance max crête Durée d impulsion Longueur d onde RADIACIÓN LÁSER NO MIRAR FIJAMENTE AL HAZ PRODUCTO LÁSER DE CLASE 2 EN 60825 1 2007 Potencia máx peak Duración del impulso Longitud de onda RADIAÇÃO LASER NÃO OLHAR FIXAMENTE O FEIXE EQUIPAMENTO LASER CLASSE 2 EN 60825 1 2007 P...
Страница 14: ...tention For error free position measurement there must be an unobstructed line of sight between the AMS 307i and the reflector 3 1 1 Mounting the device The laser is mounted using 4 screws M5 Alignment is performed using 2 adjustment screws Adjust so that the laser light spot is posi tioned at the center of the reflector The alignment is to be secured with the knurled nut and locked with the M5 nu...
Страница 15: ...e read on the display The display automatically switches to the display of the measurement values Use the up down buttons to the left of the display to read and change a wide range of data and parameters Detailed information can be found in chapter 8 3 4 SSI interface For correct data exchange between frequency inverter and AMS 307i both devices must have the same settings for the following parame...
Страница 16: ...n 7ms Resolution adjustable see chapter 9 SSI interface Temperature drift 0 1mm K Ambient temperature sensitivity 1ppm K Air pressure sensitivity 0 3ppm hPa Traverse rate 10m s Electrical data Supply voltage Vin 2 18 30VDC Current consumption 250mA 24VDC Optical data Transmitter laser diode red light Laser class 2 in accordance with IEC 60825 1 2007 CDRH Wavelength 655 nm Impulse duration 18μs Max...
Страница 17: ...nditions Operating temperature 5 C 50 C Storage temperature 30 C 70 C Air humidity max 90 rel humidity non condensing Mechanical electrical loading capacity Vibration acc to EN 60068 2 6 Noise acc to EN 60060 2 64 Shock acc to EN 60068 2 27 EMC acc to EN 61000 6 2 and EN 61000 6 4 4 1 Statistical error 1 sigma minimum switch on time 2min 2 For UL applications only for use in Class 2 circuits acc t...
Страница 18: ... TNT 35 7 24V 4 1 2 Dimensioned drawing AMS 307i Figure 4 1 Dimensioned drawing AMS 307i A M5 screw for alignment B Knurled nut with WAF4 hexagon socket and M5 nut for securing C Optical axis D Zero point of the distance to be measured A B D A C ...
Страница 19: ...e electronic 4 1 3 Type overview AMS 307i AMS 307i Type designation Description Part no AMS 307i 40 40m operating range SSI interface 50137593 AMS 307i 120 120m operating range SSI interface 50137594 Table 4 1 Type overview AMS 307i ...
Страница 20: ...e is found notify the post office or shipping agent as well as the supplier Check the delivery contents using your order and the delivery papers Delivered quantity Device type and model as indicated on the name plate Brief manual The name plate provides information as to what AMS 307i type your device is For specific information please refer to chapter 11 2 Name plates Figure 5 1 Device name plate...
Страница 21: ...vice The AMS 307i and the corresponding reflector are mounted on two mutually opposing plane parallel flat walls or system parts For error free position measurement there must be an unobstructed line of sight connection between the AMS 307i and the reflector Use M5 screws to fasten the laser measurement system Secure the screws with a toothed lock washer to protect against loosening caused by vibr...
Страница 22: ...n aligning please ensure that the knurled nut and the lock nut B in figure 5 2 are opened wide Attention To prevent the laser measurement system from moving out of alignment during continuous operation subsequently hand tighten the knurled nut and counterlock with the nut with WAF4 hexagon socket B in figure 5 2 Knurled nut and nut must not be tightened until alignment has been completed Attention...
Страница 23: ...ctronic 5 2 1 Optional mounting bracket A mounting bracket for mounting the AMS 307i on a flat horizontal surface is available as an optional accessory Type designation MW OMS AMS 01 Part no 50107255 Figure 5 3 Optional mounting bracket A Laser beam ...
Страница 24: ...ement distance To define the minimum parallel spacing between two AMS 307i it is necessary to distinguish between three different arrangements of AMS 307i and reflectors The AMS 307i are mounted stationary and in parallel on one plane Both reflectors move independently of one another at different distances to the AMS 307i Minimum parallel spacing X of the two laser light spots X 100mm max measurem...
Страница 25: ...ile manner travel tolerances could cause the two laser light spots to move towards each other Take the travel tolerances of the vehicle into account when defining the parallel spacing of adjacent AMS 307i 5 2 3 Parallel mounting of AMS 307i and DDLS optical data transmission The optical data transceivers of the DDLS series and the AMS 307i do not interfere with one another Depending on the size of...
Страница 26: ...d onto the mechanism of the US AMS 01 deflector unit The mirror can be mounted for three deflection directions 1 Upward beam deflection 2 Beam deflection to the left 3 Beam deflection to the right The deflector unit is mounted on plane parallel flat walls or plant components For error free position measurement there must be an interruption free line of sight between the AMS 307i and the deflection...
Страница 27: ...Installation and mounting 24 AMS 307i Leuze electronic 5 3 2 Dimensioned drawing of US AMS 01 deflector unit Figure 5 6 Dimensioned drawing of US AMS 01 deflector unit A Laser beam ...
Страница 28: ...AMS 307i are mounted separately Notice When mounting make certain that the laser light spot of the AMS 307i is aligned in the center of the deflection mirror Figure 5 7 Photo and dimensioned drawing of the US 1 OMS deflector unit Alignment of the laser light spot on the reflector is performed as described in chapter 5 2 A Mirror Height of the spring in non preloaded state ...
Страница 29: ...or size are provided as a function of the distance that is to be measured In any case the user must check to determine whether the recommendation is suitable for the respective application 6 2 Description of the reflective tape The reflective tape consists of a white microprism based reflective material The micro prisms are protected with a highly transparent hard protective layer Under certain ci...
Страница 30: ...face The mounting surface must be clean dry and free of grease Cutting the tape Cut with a sharp tool always on the side of the prism structure Cleaning Do not use any agents that act with a grinding effect A conventional household detergent can be used as a cleaning agent Rinse with clear water and dry the surface Storing the foil Store in a cool and dry place Part Type designation Reflective tap...
Страница 31: ...igure 6 1 Dimensioned drawing of reflectors Part Reflective tape mm Reflector plate mm xL yL XL YL L Reflective tape 200x200 M 200 200 250 250 214 Reflective tape 500x500 M 500 500 550 550 514 Reflective tape 914x914 M 914 914 964 964 928 Always align the TOP marking with the AMS connections chapter 6 4 2 ...
Страница 32: ...50115020 50115021 50115022 Voltage supply 230VAC Power 100W 600W 1800W Current consumption 0 5A 3A 8A Length of the supply line 2 m Size of the reflective tape 200x200mm 500x500mm 914x914mm Outer dimensions of the base material 250x250mm 550x550mm 964x964mm Weight 0 5kg 2 5kg 12kg Temperature control Controlled heating with the following switch on and switch off tempera tures measured at the refle...
Страница 33: ...e mm Insulated base plate mm xL yL XL YL L Reflective tape 200x200 H 200 200 250 250 214 Reflective tape 500x500 H 500 500 550 550 514 Reflective tape 914x914 H 914 914 964 964 928 18 6 5 2 L 0 5 XL 1 TOP 6 2000 115 90 XL 1 yL 1 L 0 5 YL 1 Always align the TOP marking with the AMS connections chapter 6 4 2 Connection hood Reflective tape Si cable 3 x 0 75mm ...
Страница 34: ...commended This applies in particular when the laser measurement system is mounted on a vehicle During travel the laser beam must reach the reflector without interruption For on vehicle mounting of the AMS 307i the reflector size must accommodate any travel tolerances that may arise and the associated wandering of the light spot on the reflector Overview of reflector types Recommended reflector siz...
Страница 35: ...s to achieve a base separation to the wall as well as the necessary pitch for avoiding surface reflection For further information see table 6 1 The reflector is provided with a 2m long connection cable for supplying with 230VAC Connect the cable to the closest power outlet Observe the current consumptions listed in the specifications Attention Connection work must be carried out by a certified ele...
Страница 36: ...ected to the left right upwards or down wards chapter 6 4 3 gives the correct pitch with respect to the reflector size and thus the length of the spacers Reflective tapes S and M Figure 6 3 Mounting the reflector Figure 6 4 Pitch of the reflector Pitch approx 1 Direct reflection from the triad structure Deflected surface reflection due to the pitch of the reflective tape Pitch approx 1 Spacer slee...
Страница 37: ...ve tapes H Figure 6 5 Mounting of heated reflectors Figure 6 6 Pitch of the heated reflector Pitch approx 1 Deflected surface reflection due to the pitch of the reflective tape Direct reflection from the triad structure Pitch approx 1 Spacer sleeves ...
Страница 38: ...uar anteed if other reflectors are used Reflector type Pitch resulting from spacer sleeves 1 1 Spacer sleeves are included in the delivery contents of reflective tape M and H Reflective tape 200x200 S Reflective tape 200x200 M 2 x 5mm Reflective tape 200x200 H 2 x 15mm 2 x 20mm Reflective tape 500x500 S Reflective tape 500x500 M 2 x 10mm Reflective tape 500x500 H 2 x 15mm 2 x 25mm Reflective tape ...
Страница 39: ...supply voltage agrees with the value printed on the name plate The device may only be connected by a qualified electrician Ensure that the functional earth FE is connected correctly Unimpaired operation is only guaranteed when the functional earth is connected properly If faults cannot be corrected the device should be removed from operation and protected against possible use Attention For UL appl...
Страница 40: ...dix of the manual 7 3 SSI Table 7 2 SSI pin assignment PWR 5 pin plug A coded Pin Name Remark 1 VIN Positive supply voltage 18 30VDC 2 I O 1 Switching input output 1 3 GND Negative supply voltage 0VDC 4 I O 2 Switching input output 2 5 FE Functional earth Thread FE Functional earth housing PWR I O 2 I O 1 3 2 1 4 5 GND VIN FE M12 plug A coded SSI 5 pin plug B coded Pin Name Remark 1 DATA Data line...
Страница 41: ...igned only for use by Leuze electronic Service 5 pin socket A coded Pin Name Remark 1 NC Not used 2 RS232 TX Transmission line RS 232 service data 3 GND Voltage supply 0VDC 4 RS232 RX Receiving line RS 232 service data 5 NC Not used Thread FE Functional earth housing SERVICE 1 2 3 4 NC NC RS232 RX RS232 TX GND 5 M12 socket A coded ...
Страница 42: ...atus and warning messages in the display IO1 Input 1 or output 1 active Function depending on configuration IO2 Input 2 or output 2 active Function depending on configuration LSR Warning laser prefailure message Laser diode old device still functional exchange or have repaired TMP Warning temperature monitoring Permissible internal device temperature exceeded not met Status display Bar graph LED I...
Страница 43: ...ight The center bar represents the ATT warning threshold The distance value remains valid and is output at the interfaces If no bar graph is available the PLB status information appears at the same time The measurement value has thus been assessed as being implausible Depending on the configuration either zero or the last valid measurement value is output at the interfaces Interface info The abbre...
Страница 44: ...n continuous light Power LED green AMS 307i ok Measurement value output Self test successfully finished Device monitoring active Red flashing Power LED flashes red Device ok but warning message ATT TMP LSR set in display Light beam interruption Plausibility error PLB Red continuous light Power LED red No measurement value output for details see Display Orange continuous light Power LED orange Para...
Страница 45: ...ithin a level are selected with the up down buttons The selected menu item is activated with the enter button Press the ESC button to move up one menu level When one of the buttons is actuated the display illumination is activated for 10min Setting values If input of a value is possible the display looks like this Use the and buttons to set the desired value An accidental incorrect entry can be co...
Страница 46: ...i 120 Leuze electronic GmbH Co KG SW V 1 3 0 HW 1 SN Device information main menu This menu item contains detailed information on Device model Manufacturer Software and hardware version Serial number No entries can be made via the display IO1 LSR PLB IO2 TMP ATT ERR SSI 87 000m Status and measurement data main menu Display of status warning and error messages Status overview of the switching input...
Страница 47: ... of diagnostic data No entries can be made via the display See Service menu on page 48 Table 8 1 Parameter handling submenu Level 3 Level 4 Level 5 Selection configuration option Description Standard Parameter enabling ON OFF The standard setting OFF prevents unintended parameter changes With parameter enabling activated ON the display is inverted In this state it is possible to change parameters ...
Страница 48: ...al states in the error bit are processed in an OR function Plausibility PLB Hardware ERR Update rate 1 7 0 2ms 1 7 Clock frequency 50 79kHz 80 800kHz Selection of the clock frequency 80 800kHz Table 8 3 Position value submenu Level 3 Level 4 Level 5 Selection configuration option Description Standard Measurement unit Metric Inch Specifies the units of the measured distances Metric Count direction ...
Страница 49: ...y PLB Hardware ERR The individual functions are ORed on the selected switching out put Plausibility PLB hardware ERR Activation Low active High active Low active I O 2 Port config uration Input Output Defines whether I O 2 functions as an output or input Output Switching input Function No function preset teach laser ON OFF No function Activation Low active High active Low active Switching output F...
Страница 50: ...nation is switched off after 10 minutes or if the parameter is set to ON illumination is always on 10min Display contrast Weak Medium Strong The display contrast may change at extreme temperature values The contrast can subsequently be adapted using the three levels Medium Service RS232 Baud rate 57 6kbit s 115 2kbit s The service interface is only available to Leuze internally 115 2kbit s Format ...
Страница 51: ...preset to English To change the language no password needs to be entered nor must password enabling be activated The display language is a passive operational control and is thus not a func tion parameter per se 8 3 4 Service menu A more detailed description of the individual functions can be found in chapter 10 Language selection o Deutsch English o Español o Français Service Status messages Diag...
Страница 52: ...nabling below Inthemainmenu presstheenterbuttontoenterthe Parameter menu Parameter Parameter handling SSI Position value I O Other Use the buttons to select the Parameter handling menu item Press the enter button to enter the Parameter handling menu Parameter handling o Parameter enabling o Password Parameters to default In the Parameter handling menu use the buttons to select the Parameter enabli...
Страница 53: ...enu presstheenterbuttontoenterthe Parameter menu Parameter Parameter handling SSI Position value I O Other Use the buttons to select the Parameter handling menu item Press the enter button to enter the Parameter handling menu Parameter handling o Parameter enabling o Password Parameter default In the Parameter handling menu use the buttons to select the Password menu item Press the enter button to...
Страница 54: ...assword Activate password Password entry In the Password menu use the buttons to select the Password entry menu item Press the enter button to enter the Password menu Password entry 0815 0123456789 save Default unit 0000 Now enter the password digits See Setting values on page 42 Press the ESC button twice to return to the Param eter menu ESC ESC ...
Страница 55: ...ine After the least significant bit LSB has been output the clock signal switches from LOW to HIGH for one last time and the data line switches to LOW level end of transmission A monoflop retriggered by the clock signal determines the time span before the SSI interface can be called for the next transmission This results in the minimum pause time between two successive clock cycles If time tm 20μs...
Страница 56: ...t is not included in the Gray encoding of the measurement value The error bit is 1 active 0 not active Notice The data can be read out with a clock rate between 80kHz and 800kHz Attention Updating the measurement values on the SSI interface of the AMS 307i The measurement value on the SSI interface of the AMS 307i is updated every 1 7ms de fault independent of the clock frequency The update rate o...
Страница 57: ... cable length as a function of the clock rate 9 2 SSI electrical connection Figure 9 2 SSI electrical connection Notice To connect the SSI interface we recommend our ready made SSI cables see chapter 11 4 5 Data rate 80kBit s 100kBit s 200kBit s 300kBit s 400kBit s 500kBit s 1 000kBit s Max cable length typical 500m 400m 200m 100m 50m 25m 10m SSI CLK 3 2 1 4 FE DATA CLK DATA 5 SSI connector 5 pin ...
Страница 58: ...nt value 1 bit error error 1 active error bit LSB Resolution 0 1mm Default error bit Plausibility error or hardware error Update rate 1 7ms Measurement unit Metric Count direction Positive the SSI interface cannot represent negative values I O 1 Output plausibility error or hardware error I O 2 Output temperature error intensity error or laser prefailure message Static preset 000 000 Dynamic prese...
Страница 59: ... The status messages are written in a ring memory with 25 positions The ring memory is organized according to the FIFO principle No separate activation is necessary for storing the status messages Power OFF clears the ring memory Basic representation of the status messages n Type No 1 Meaning n memory position in the ring memory Type type of message I info W warning E error F severe system error N...
Страница 60: ...tes the diagnostics function and clears the contents of the recordings The recorded diagnostic data are displayed in 2 fields In the upper half of the display status messages of the AMS 307i and the bar graph are displayed The lower half contains infor mation that assists in a Leuze internal evaluation Use the up down buttons to scroll in the bottom half between various displays The contents of th...
Страница 61: ...are error Send in device PWR LED flashes red Light beam interruption Check alignment Plausibility error Traverse rate 10m s PWR LED static red Hardware error For error description see display It may be necessary to send in the device Table 10 1 General causes of errors Error Possible error cause Measure BUS LED OFF No supply voltage connected Check supply voltage Incorrect wiring Check wiring SSI ...
Страница 62: ...perature far outside of the permissible range TMP display PLB Provide cooling ATT insufficient received signal level Reflector soiled Clean reflector or glass lens Glass lens of the AMS soiled Performance reduction due to snow rain fog con densing vapor or heavily polluted air oil mist dust Optimize usage conditions Laser spot only partially on the reflector Check alignment Protective foil on the ...
Страница 63: ...cription Part no Reflective tape 200x200 S Reflective tape 200x200mm self adhesive 50104361 Reflective tape 500x500 S Reflective tape 500x500mm self adhesive 50104362 Reflective tape 914x914 S Reflective tape 914x914mm self adhesive 50108988 Reflective tape 200x200 M Reflective tape 200x200mm affixed to aluminum plate 50104364 Reflective tape 500x500 M Reflective tape 500x500mm affixed to aluminum...
Страница 64: ...essory mounting bracket Type designation Description Part no US AMS 01 Deflector unit with integrated mounting bracket for the AMS 307i Variable 90 deflection of the laser beam in various directions 50104479 US 1 OMS Deflector unit without mounting bracket for simple 90 deflection of the laser beam 50035630 Table 11 4 Accessory deflector unit Type designation Description Part no KD 02 5 BA M12 con...
Страница 65: ...ded Pin Name Core color 1 VIN brown 2 I O 1 white 3 GND blue 4 I O 2 black 5 FE gray Thread FE bare Operating temperature range in rest state 30 C 70 C in motion 5 C 70 C Material sheathing PVC Bending radius 50mm Type designation Description Part no KD U M12 5A V1 050 M12 socket A coded axial plug outlet open cable end cable length 5m 50132079 KD U M12 5A V1 100 M12 socket A coded axial plug outl...
Страница 66: ...ction cable 5 pin socket B coded Pin Name Core color 1 DATA yellow 2 DATA Green 3 CLK gray 4 CLK pink 5 FE brown Thread FE bare Operating temperature range in rest state 40 C 80 C in motion 5 C 80 C Material free of halogens silicone and PVC Bending radius 80mm suitable for drag chains SSI FE DATA CLK CLK DATA 1 2 3 4 5 M12 socket B coded All conductor pairs stranded colors in accordance with DIN ...
Страница 67: ... IBS 10000 BA M12 socket B coded for SSI Interbus axial connector open cable end cable length 10m 50104170 KB SSI IBS 15000 BA M12 socket B coded for SSI Interbus axial connector open cable end cable length 15m 50104169 KB SSI IBS 20000 BA M12 socket B coded for SSI Interbus axial connector open cable end cable length 20m 50104168 KB SSI IBS 25000 BA M12 socket B coded for SSI Interbus axial conne...
Страница 68: ... on the device except where expressly described in this operating man ual are not authorized The device must not be opened Failure to comply will render the guarantee void Warranted features cannot be guaranteed after the device has been opened Repairs to the device must only be carried out by the manufacturer Contact your Leuze distributor or service organization should repairs be required The ad...
Страница 69: ...s 56 Dimensioned drawing of AMS 3xxi 15 Display 39 E Electrical connection 36 Safety notices 36 Expanded diagnostics 57 Explanation of symbols 4 F Fast commissioning 11 G General causes of errors 58 H Heated reflectors Dimensioned drawing 30 Technical data 29 I Installation 17 Interface errors 58 Interface info in display 40 Internal hardware error 40 L LSR status display 59 M Main menu Device inf...
Страница 70: ...tch 35 Size 31 Type overview 31 Repair 65 Response time 13 S Servicing 65 SSI 52 Default settings 55 Electrical connection 54 Status and measurement data main menu 43 Status and warning messages 39 Status display 39 ATT 59 ERR 59 PLB 59 TMP 59 Status display in the display 59 Status displays 41 Status messages 56 Storage 17 Storage temperature 14 Supply voltage 13 Surface reflections 33 Symbols 4 ...
Страница 71: ...laser LSR plausibility PLB hardware ERR Update rate 1 7ms 0 2ms Clock frequency 80kHz 800kHz 20us 50kHz 79kHz monoflop time 30us Position value Measurement unit Metric Inch page 45 Count direction Positive Negative Offset Value input Preset Value input Error delay ON OFF Position value in the case of error Last valid value zero I O I O 1 Port configuration Input Output page 46 Switching input Func...
Страница 72: ...e input in mm or inch 100 Max velocity Activation ON OFF Max velocity Value input in mm s or inch 100s Other Display background 10 minutes ON page 47 Display contrast Weak Medium Strong Service RS232 Baud rate 57 6kbit s 115 2kbit s Format 8 e 1 8 n 1 Language selection Deutsch English Español Français Italiano page 48 Service Status messages Number of readings reading gates reading rate non readi...