Device parameters and interfaces
62
AMS 200
Leuze electronic
8
.1.6.10 Module 10: Velocity
Description
Outputs the current velocity with the configured resolution. The unit (metric or inch) is set in
module 1 (position value) and also applies to the velocity. If module 1 is not configured, the
AMS 200… operates with the default unit (metric).
The sign of the velocity is dependent on the count direction in module 1d.
In the default setting a positive velocity is output when the reflector moves away from the
AMS 200… When the reflector moves towards the AMS 200…, negative velocities are
output. If the "negative" count direction is configured in module 1, the velocity signs are
reversed.
Measurement value preparation averages all velocity values calculated during the selected
period to yield a velocity value.
Parameter
Hex coding of the "velocity" parameter
The value listed in this table shows the hex coding of the default settings:
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Velocity
resolution
The parameter specifies the res-
olution for the velocity value.
0.0…
0.2
Bit
001=1: 1
010=2: 10
011=
3
: 100
100=4: 1000
1
mm/s
(in/
100)
/s
–
Average
The parameter specifies the inte-
gration time (averaging time) of
the calculated velocity values.
0.
3
…
0.5
Bit
000=0: 2
001=1: 4
010=2: 8
011=
3
: 16
100=4:
3
2
101=5: 64
110=6: 128
3
ms
–
Parameter length: 2 bytes
a
b
Modul
e ad
dress
V
e
loci
ty r
esol
u
ti
on
A
ver
a
g
e
0A
00 19