Leuze electronic AKS 171.2 Скачать руководство пользователя страница 7

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

AKS 171.2… - 01

[email protected]  •  www.leuze.com

Setting

Before adjusting, the transmitter and receiver must be aligned as described in sections "Preparations" and "Alignment."

Objectives:

Adjust the transmitter and receiver so that the required sensitivity is achieved.

Reliable, fault-free detection of small objects.

1.

Set switch 

 on the receiver to the minimum object size (position '

4

').

2.

Turn the potentiometer 

 on the transmitter clockwise at least 4 full rotations (maximum position).

3.

With the light axis free, slowly turn potentiometer 

 counterclockwise until the red illumination LED 

 just switches off (at max-

imum distance between transmitter and receiver (1700 mm), this is, under certain circumstances, the case even without turning 
back the potentiometer).

4.

Interrupt and again clear the light axis several times to check whether the red illumination LED 

 reliably switches off each time.

5.

If not, turn potentiometer 

 on the transmitter counterclockwise approx. ¼ turn and repeat the previous step.

6.

The system is correctly adjusted if:

- all 3 yellow LEDs of the alignment indicator 

 illuminate

- the red LED 

 does not illuminate with free light paths (it may, however, illuminate if objects are in the light path).

7.

Transmitter:

remount potentiometer cover on the potentiometer 

Receiver:

use switch 

 to set object size.

Function test

1. Transmitter

:

green LED 

 and yellow LED 

 must illuminate.

2. Receiver

If light path is free

:

- Red  LED 

 (signal) must illuminate constantly (not flash).

- All 3 yellow LEDs in the alignment indicator 

 illuminate.

- Red  LED 

 (illumination indicator) must not illuminate.

If there are objects in the light path

:

- Yellow LED 

 (state output on receiver) illuminates -> object detected. 

- Red  LED 

 (receiver signal strength) on the rear side of the receiver switches off while large objects

1)

 are located in the light 

path. For smaller objects, it illuminates constantly or flashes.

- Red  LED 

 (illumination indicator) illuminates upon detection; is dark, however, if the light path is free.

Trouble shooting

1) Large object = light path is fully or largely darkened.

Fault image

Error

Possible remedy

Sensor: both LEDs 

 off

Supply voltage missing or polarity 
reversed or transmitter defective

Check power supply unit / wiring, exchange device 
if necessary and send to manufacturer for repair.

Transmitter: green LED 

 illumi-

nates, yellow LED

 off

Transmitter deactivated

Connect pin 4 (black wire) to pin 3 (blue wire) or 
isolate pin 4 (black wire).

Receiver: both LEDs 

 dark

Supply voltage missing or receiver 
defective

Check power supply unit / wiring; replace receiver 
if necessary.

Red LED 

 (signal indicator) off, yel-

low LED 

 illuminates continuously, 

switching output active

No or very weak signal received from 
transmitter (light path interrupted, 
large object, massive soiling, potenti-
ometer 

 on transmitter misadjusted) 

or transmitter without supply or trans-
mitter defective or transmitter/receiver 
alignment very bad

Check whether light path is free, check whether 
transmitter is active (both LEDs 

 on).

Check transmitter adjustment (potentiometer 

and alignment.

Red LED 

 (signal indicator) flashes, 

yellow LED 

 off

Object in the light path, weak recep-
tion signal, sensor is at the function 
limit but still just managing to function

Check whether light path is free. Clean optics with 
lint-free cloth and alcohol, check alignment, check 
potentiometer adjustment 

 on transmitter.

AKS 171.2

Ejection monitoring

Содержание AKS 171.2

Страница 1: ...tentiometer transmitter Exact time saving alignment though indica tor LEDs bar graph and variation of the transmitting power Static and dynamic monitoring in the range between 300 1700 mm Static detec...

Страница 2: ...g output 500 ms Dark pulse 5 ms Electrical data Operating voltage UB 24 V DC 15 Residual ripple 15 of UB Current consumption max Transmitter 60 mA Receiver 60 mA Outputs Warning output QW PNP Switchin...

Страница 3: ...nit AKS 171 2 4 5 1SE S12 50138388 Receiver unit with protection cap 15 mm deep AKS 171 2 4 5 1E S12 50138389 Set consisting of transmitter 50138388 and receiver 50138389 SET AKS 171 2 4 5 1 S12 50140...

Страница 4: ...ing weak reception signal On good reception signal Yellow LED switching output state 2 states On active Off inactive Rotary switch Object size 4 positions 4 object size 0 5 1 0mm 3 object size 1 0 1 5...

Страница 5: ...band lower edges of the lens below the upper edge of the chute 3 6 Electrically connect transmitter and receiver Mount cable plugs and tighten coupling rings Note the different wiring of transmitter a...

Страница 6: ...n the alignment indicator illuminate 3 With the potentiometer adjustment from step 2 further optimize transmitter and receiver along the X axis and try to again illu minate all 3 yellow LEDs of the al...

Страница 7: ...dicator must not illuminate If there are objects in the light path Yellow LED state output on receiver illuminates object detected Red LED receiver signal strength on the rear side of the receiver swi...

Страница 8: ...acent parts with dark matt paper or similar for test purposes Exchange devices if necessary and send to manu facturer for repair Small parts are not reliably detected Incorrect adjustment and or align...