7.4.2 Width offset
The width offset is important if the smallest distance between the object and a conveyor edge is to be
measured. The measuring resolution of the distance determines the beam distance of the light curtain
and is 5mm.
NOTICE
Determining the width offset
Make sure that the transmitter and receiver of the wide light curtain are correctly aligned
, see
chapter
Determine on which side of the width light curtain the first beam is located.
Measure the shortest distance between beam 1 and the outer edge of the conveyor in
millimeters, see Figure 33.
Note the value here.
Enter the offset value with a negative sign in WebConfig, see chapter 0.
Figure 33: How to determine the width offset