Leuze electronic
CMS 700i
– Contour Measurement System
Page 36
7.2 Setting up the system coordinate origin
In order for the system to output measured values, overhangs and bulges correctly, the system
coordinate origin must be set up.
7.2.1 Setup with 3 light curtains
In Figure 29, mark the respective positions of the
connection sides
of the light curtains.
NOTICE
Observe the specifications of the conveying direction!
Figure 29: Determination of the coordinate origin for 3 light curtains. The conveying direction in the left picture comes
out of the sheet.
NOTICE
Evaluation of Figure 29!
Select your installation scenario from the table below.
Mark your installation scenario in color in the table below!
Depending on the existing installation situation, the counting direction of one or more light
curtains may have to be inverted.
The word light curtain is abbreviated with CML.
Please make the settings in WebConfig according to chapter 8.2.1.1.
Install. scenario
Width CML
Height CML
Length CML
Settings WebConfig
1
Left
Below
Left
-
2
Left
Below
Right
Length:
Reverse counting direction
3
Left
On top
Left
Height:
Reverse counting direction
4
Left
On top
Right
Length and Height:
Reverse counting direction
5
Right
Below
Left
Width:
Reverse counting direction
6
Right
Below
Right
Length, width:
Reverse counting direction