background image

DMU330-3500…-M12 - 01

2017/02

DMU330-6000…-M12 - 01

1-point teach of the analog output

First activate the previously described teach mode for output Analog OUT.

By selecting an object distance within the scanning range, the characteristic curve of the analog output can be adjusted.

If an object is located outside of the taught measurement range, an error signal is output. A different analog signal is output here by the 
sensor for the errors "distance too close: object outside of the measurement range" and "distance too far: object outside of the 
measurement range".

2-point teach of the analog output

First activate the previously described teach mode for output Analog OUT.

By selecting 2 object distances within the scanning range, the characteristic curve of the analog output can be adjusted. 

If an object is located outside of the taught measurement range, an error signal is output. A different analog signal is output here by the 
sensor for the errors "distance too close: object outside of the measurement range" and "distance too far: object outside of the 
measurement range".

Inverting the analog output (falling/rising characteristic curve)

First activate the previously described teach mode for output Analog OUT.

The characteristic curve of the analog output can be inverted, e.g., if a falling characteristic output curve is desired. 

1-point teach - rising characteristic curve 

1. Place

 object at desired distance for the end point of the measurement range.

Note

:

The 

minimum object distance for the end of the measurement range

 is as follows:

scanning range of 3500mm:

600mm

scanning range of 6000mm:

950mm

2.

To adjust analog output 

Analog OUT

press

 the 

teach button

 for 

2 … 7s

 

until the 

blue and green LEDs flash simultaneously at 3Hz

.

3. Release the button

. The characteristic curve with plot rising from the start of the range (50 mm or 150 mm) to the set object distance was taught in. 

4.

Error-free teach: LED states acc. to "Technical data" -> "Indicators". 

Faulty teach: green and blue LEDs flash at 8Hz

 until an error-free teach is performed.

2-point teach - rising characteristic curve 

1. Position

 the object at the first desired distance (near or far).

2.

To adjust analog output 

Analog OUT

press

 the 

teach button

 for 

7 … 12s

 until the 

blue and green LEDs flash alternately at 3Hz

.

3. Release the button

. The sensor remains in teach mode and the LEDs continue to flash. 

4.

Then 

position

 the object at the second desired distance (far or near). 

Note

:

the 

minimum object distance between the start and end point of the measurement range

for a scanning range of 3500mm is:

350mm

for a scanning range of 6000mm is:

600mm

5. Briefly press

 the 

teach button

 again to complete the teach event. 

The characteristic curve with rising plot from the near to the far object distance was taught in. 

6.

Error-free teach: LED states acc. to "Technical data" -> "Indicators". 

Faulty teach: green and blue LEDs flash at 8Hz

 until an error-free teach is performed.

Inverting the characteristic curve 

1.

To invert the characteristic curve of the analog output 

Analog OUT

press

 the 

teach button

 for 

> 12s

 until the 

blue and green LEDs flash alternately

.

2. Release the button

. The characteristic curve plot was inverted.

The 

blue LED

 indicates the current setting of the analog output: 

ON

rising

 characteristic curve

OFF

falling

 characteristic curve

DMU330

Содержание 50136112

Страница 1: ...itching output PNP or NPN NO NC function reversible NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 250 3500mm 350 6000mm 12 30 V DC 4 20mA 0 10V Accessories available separately Mounting systems Cables with M12 connector KD IP 67 IEC 60947 IEC 60947 Dimensioned drawing A Active sensor surface B Teach in button C Indicator d...

Страница 2: ...Teach in button 12s Indicators Yellow LED OUT1 object detected Blue LED Analog OUT object detected Yellow green or blue green LED flashing Teach in teaching error Green LED Object within the scanning range Mechanical data Housing Plastic PBT Active surface Epoxy resin glass fiber reinforced Weight 140g 170g Ultrasonic transducer Piezoceramic 7 7 The ceramic material of the ultrasonic transducer co...

Страница 3: ...tact preset N NPN output NC contact preset Pin assignment of connector pin 2 white cable wire Analog OUT OUT2 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset C Analog output 4 20mA V Analog output 0 10V Pin assignment of connector pin 5 gray cable wire Sync MUX K Synchronization multiplex input Connection technology M12 M1...

Страница 4: ...rmally closed Close Far Far Close Dead zone Sensor OUT1 active Yellow LED ON Green LED OFF OUT1 not active Yellow LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT1 not active Yellow LED OFF Green LED OFF OUT1 not active Yellow LED OFF Green LED OFF Dead zone Sensor OUT1 not active Yellow LED OFF Green LED ON OUT1 active Yellow LED ON Green LED OFF Distance Hysteresis Swi...

Страница 5: ...e table Switching behavior with 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the output OUT1 press the teach button for 2 7s until the yellow LED flashes at 3Hz 2 To adjust the output OUT1 press the teach button for 7 12s until the yellow and green LEDs ...

Страница 6: ...g output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 Changeover of the switching function 1 To change the switching function of output OUT 1 press the teach button for longer than 12s The current state of output OUT 1 is frozen during the adjustment process 2 The green and yellow LEDs flash alternately at 3Hz If the yellow LED is ON ...

Страница 7: ...ed however Selecting the output that is to be taught OUT1 or Analog OUT 1 Press the teach button for 2s to activate teach mode The yellow LED OUT 1 flashes at 1Hz While in this state output OUT 1 can be taught 2 To teach output Analog OUT briefly press the teach button again The blue LED Analog OUT now flashes at 1Hz While in this state output Analog OUT can be taught 3 Briefly press the teach but...

Страница 8: ...ng range of 3500mm 600mm scanning range of 6000mm 950mm 2 To adjust analog output Analog OUT press the teach button for 2 7s until the blue and green LEDs flash simultaneously at 3Hz 3 Release the button The characteristic curve with plot rising from the start of the range 50 mm or 150 mm to the set object distance was taught in 4 Error free teach LED states acc to Technical data Indicators Faulty...

Страница 9: ...diagram A synchronization pulse from the control activates synchronous operation The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual sensors in the network corresponds approximately to that of a single sensor Synchronous operation wiring schematic Timing diagram for synchronous operation Working distance Minimum mounting distance 1 5...

Страница 10: ...on press the teach button for 5s 2 Release the button The green yellow and blue LEDs flash alternately and very quickly for a brief time The sensor was reset to the factory setting switching output 1 switching point at 3500mm or 6000mm 1 point teach static analog output 4 20mA or 0 10V corresponds to an object distance of 250 3500 mm or 350 6000 mm respectively Sensor 2 Sensor 1 Sensor n NOTE Plea...

Отзывы: