background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

[email protected]  •  www.leuze.com

We

 re

serve 

th

right

 t

o

 ma

ke

 c

h

an

ges 

• 

PA

L_LV463

XV

1

S

WO

_e

n_501

3533

9.f

m

Extremely short response time

Two, large, easy-to-read displays for the 
simultaneous display of the signal value 
and the switching threshold

Simple operation and easy-to-understand
menu functions for optimum configuration

Internal multiplex operation of up to six 
units 

Line teach or external transmitter activation  

Three different teach modes for fast sensor 
adjustment

Switch for changing between light and dark 
switching

A PNP or NPN switching output

Indicator diode for operation and switching 
output

Connection via M8 connector, cable or 
cable with M12 connector

Up to 
1700mm

Up to 
450mm

10 - 30 V

DC

Accessories:

(available separately)

Plastic fiber optics (KF, KFX)

Glass fiber optics (GF)

Ready-made cables (KB …)

Mounting device (BTU LV463)

IEC 60947...

IEC 60947...

Dimensioned drawing

A

Clamping lever for fiber optic cable (unlock in direction of arrow)

B

Connection for fiber optics receiver

C

Connection for fiber optics transmitter

35

10

Mounting accessories

With M8 connector

With cable

BTU LV463

 

Part no. 50120869

Electrical connection

4-pin connector

4-wire cable

multi funct

:

-  OFF
- Line teach
- Activation input
- Multiplex operation

Details 

 

Description of the subfunctions

NOTE

: Open lead wires must be connected to a terminal box.

LV463.XV

High-speed amplifier with 1 switching output for fiber optics

   LV463.XV 1SWO - 02

en

02

-2

01

8/

06

5

0

1

353

39

Содержание 50133962

Страница 1: ...ration and switching output Connection via M8 connector cable or cable with M12 connector Up to 1700mm Up to 450mm 10 30 V DC Accessories available separately Plastic fiber optics KF KFX Glass fiber optics GF Ready made cables KB Mounting device BTU LV463 IEC 60947 IEC 60947 Dimensioned drawing A Clamping lever for fiber optic cable unlock in direction of arrow B Connection for fiber optics receiv...

Страница 2: ...tor 63g with 2000mm cable 70g with 150mm cable and M12 connector Connection type M8 connector 4 pin or 2000mm cable 4 x 0 25mm2 or 150mm cable with M12 connector 4 pin Fiber optic connection Clamp mounting 2 x Ø 2 2mm Environmental data Ambient temp operation storage 10 C 55 C 20 C 85 C Protective circuit 5 5 2 polarity reversal protection 3 short circuit protection for all outputs 2 3 Degree of p...

Страница 3: ...pin 2 white cable wire multi funct OUT2 T Multifunction input teach activation or multiplex operation 4 PNP transistor switching output light switching Connection technology Not specified Connection cable standard length 2000mm 4 wire M8 M8 connector 4 pin 150 M8 Cable length 150mm with M8 connector 4 pin 150 M12 Cable length 150mm with M12 connector 4 pin With one switching output and multifuncti...

Страница 4: ...Operating and display elements The amplifier is mounted as shown on a TS 35 DIN rail while disconnected from voltage Alternatively the amplifier can also be mounted without a DIN rail using the mounting accessory and M3 screws DIN rail TS 35 35mm x 7 5mm DIN rail TS 35 35mm x 7 5mm Spring mounted DIN rail mount Slide switch switching output light LO dark DO switching Lever for fiber optic clamp Sl...

Страница 5: ... output dark switching The switching behavior is the inversion of the light switching setting Rocker push button Set switching threshold Navigation in menu The rocker push button can be rocked to the right and to the left and pressed in the middle position Rock In the ADJ operating mode the switching threshold can be increased or decreased by rocking In the PRG operating mode rock to navigate in t...

Страница 6: ... teach process To trigger the teach event see Teaching operating mode 1 point teach static during teaching the current signal value is accepted as the new switching threshold Actuate the rocker push button to make fine adjustments to the threshold 2 point teach static the switching threshold is calculated at approxi mately midway between two signal values e g teach to two different objects or teac...

Страница 7: ...s can be synchronized with one another in multiplex operation Here exactly one master and 1 5 slaves are always needed Settings for master mA n number Defines that this unit functions as a master and a total of n sensors were wired in parallel Value range n 2 6 Example mA 4means unit is the master a total of 4 sensors are wired to one another via the multi funct multifunction input Setting for sla...

Страница 8: ...ing threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Switching threshold Time t Time t Signal OUT Rising edge Falling edge Active state of the switching output Set delay time 0 9999ms LV463...

Страница 9: ...pears on the red display In this case the signal value may be too small and cannot be accepted as a teach value Table with minimum teach values as a function of the setting Check object and or placement and repeat event 2nd appears on the green display the red display shows the current signal value Place object 2 or object at distance 2 and press the rocker push button within one minute The second...

Страница 10: ...ction begins with the rising edge tTeach 20 80ms Operating mode selector switch locked The teach event begins with the fall ing edge 1 Static 1 point teach The current signal value is taken over as the teach value with the falling edge 2 Static 2 point teach The current signal value is taken over as teach value 1 with the falling edge 3 Dynamic teach The sensor begins to scan the sig nal values wi...

Страница 11: ...funct multifunction inputs pin 2 ws WH are connected in parallel For settings see subfunctions Maximum 6 minimum 2 units 1 x master 1 5 slaves Each unit can be either a master mA or slave SL The master also requires the information on the number of units connected in parallel n 1 number of slaves Each slave also receives an individual address 1 5 max The master generates a timing signal on pin 2 o...

Страница 12: ...n identical address from 1 5 Result Master and slaves have a time offset of 1 5 ms slaves with the same address operate synchronously Model 2 Synchronous operation through an external activation signal at the multi funct input pin 2 ws WH Subfunction setting Function InP SEL multi funct input SYnc PLc activation input multi funct activation input pin 2 ws WH Transmitter OFF Transmitter OFF Transmi...