![Leuze electronic 50038948 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/leuze-electronic/50038948/50038948_original-operating-instructions_1883900038.webp)
Installation
36
BCL 8
Leuze electronic
6.3.2
Connecting the switching input/output
The BCL 8 is provided with a switching input or a switching output. You can configure the
respective function (input or output) according to your requirements using the supplied
BCLConfig software.
Switching input (default)
By means of the SW IN/OUT combined switching input/output connection, you can trigger a
read process in the standard setting (low = active) with the connection SW IN/OUT (pin 5)
and GND (pin 3). The 2.2 k
"pull-up" resistor must be connected externally (connection
version 1, Figure 6.4).
Figure 6.4: Switching input for BCL 8 connection version 1 (standard setting)
With the "inverted" setting (high = active), you can trigger a read process by applying a
voltage of +5 V DC (pin 1) at SW IN/OUT (pin 5) (connection version 2, Figure 6.5).
Figure 6.5: Switching input for BCL 8 connection version 2 (setting "inverted")
+ 5 V DC
SW_IN/OUT
GND
BCL 8
4.75 … 5.5 V DC
GND
2.2 k
1
5
3
Input resistance 36 k
Connection version 1: standard setting (low = active)
+ 5 V DC
SW_IN/OUT
GND
BCL 8
GND
1
5
3
4.75 … 5.5 V DC
Input resistance 36 k
Connection version 2: setting "inverted" (high = active)
UM_BCL8_de_50040581.book Seite 36 Montag, 24. Februar 2020 9:53 09