![Leuze electronic 50038948 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/leuze-electronic/50038948/50038948_original-operating-instructions_1883900030.webp)
Accessories/order codes
28
BCL 8
Leuze electronic
5.3.2
MA 8
-
01 - SW IN/OUT - switching input and switching output
Figure 5.1: MA 8-01 - Pin assignment SW IN/OUT
SW IN/OUT (5-pin socket, A-coded)
Pin
Name
Comment
1
VOUT Voltage supply for sensor system (VOUT
identical to VIN at PWR IN)
2
SWOUT Switching output
3
GND
GND for the sensor system
4
SWIN Switching input
5
FE
Functional earth
Thread
FE
Functional earth (housing)
1
2
3
4
5
SWIN
VOUT
GND
FE
SWOUT
SW IN/OUT
M12 socket
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
NOTE
The switching input/switching output are programmed via the parameters in the BCLconfig
configuration software. For more information see also Chapter 10.6 and Chapter 10.8,
ATTENTION!
If you use a sensor with a standard M12 connector, then please note the following:
Use only sensors on which the switching output does not lie on pin 2 or sensor cables
on which pin 2 is not assigned. Otherwise, the switching output is not protected against
feedback on the switching input. If the inverted sensor output lies on pin 2, erroneous
behavior of the switching output will result.
UM_BCL8_de_50040581.book Seite 28 Montag, 24. Februar 2020 9:53 09