Important parameters
54
BCL 8
Leuze electronic
10.6
Switching input tab
Figure 10.8: Switching input tab
Inverted
Here, the input level can be inverted
Release
Switching input enabled or disabled
Debounce time
This time period must lapse until the trigger signal is regarded as
valid.
Switch-on delay
The trigger signal is passed on delayed by the specified time period.
Pulse duration
If the value is higher than "0": duration of the activation, regardless of
how long the trigger signal has been present.
Switch-off delay
After the end of the trigger signal, the pulse is extended internally by
this time period.
NOTE
If the switch-off delay is activated, the parameter "pulse duration" should be "0".
Function
Event that is started when the switching input is activated.
ATTENTION!
Depending on wiring, either a switching input or a switching output is available on the
BCL 8.