22
CENTERING WINDAGE AND ELEVATION ADJUSTMENTS
TO ACHIEVE OPTIMUM ADJUSTMENT TRAVEL
Making windage and elevation adjustments moves the entire erector system
horizontally and vertically inside the scope. If the erector system is off to one
side – as a result of having been mounted on a non-adjustable mount – the
adjustments won’t provide equal travel in all directions. To regain full balanced
travel, you must recenter the adjustment as follows:
1.
Turn the windage adjustment to the point that it stops moving.
2.
Counting the clicks or hash marks, turn it all the way in the other direction.
3.
Turn the dial back half the amount of clicks or hash marks counted.
4.
Repeat this process for the elevation adjustment.