Prime Series
16 of 20
User’s Manual
13. LED INDICATORS
The charger includes one (1) local LED that can display three (3) colors to indicate charger status and fault
information (see Figure 5-1). The functionality of the LED is outlined below. If an optional remote LED is
being used, it will provide the same functionality.
Amber (Charge Status)
Indicates charge cycle status. See Figure 13-1 for descriptions of the possible states.
Green (Charge Status)
Indicates when a charge cycle completes successfully, when an extended Balance/Equalize charge cycle
phase is active, or when a post-charge phase is active. See Figure 13-1 for descriptions of the possible
states.
Red (Fault)
Indicates when a charger or battery fault has occurred. See the FAULTS section.
Amber
(Charge Status)
Green
(Charge
Complete)
Description
Slow Blink
Off
Bulk/Start charge cycle phase (constant power or
constant current).
Fast Blink
Off
Absorption/Plateau charge cycle phase (constant
voltage). Greater than 80% charged.
Solid On
Off
Finish charge cycle phase (constant current). Not all
charge profiles include a Finish phase.
Off
Fast Blink
Balance/Equalize phase. An extended charge cycle
is occurring because a trigger condition has been
met (cycle count, etc). Not all charge profiles include
a Balance/Equalize phase.
Off
Solid On
Charge cycle complete.
Off
Slow Blink
Charge cycle complete. Post Charge phase (constant
voltage float, etc). Not all charge profiles include a
Post Charge phase.
Figure 13-1: Charger LED States (Non-Fault)