Troubleshooting Guide

8

31039B

Figure 1

Figure 2

L2115S88

L2115S89

Transformer Coil Voltage Test

36 Volt Charger (Without Capacitor)

Transformer Coil Voltage Test

36 Volt Charger (With Capacitor)

TEST RESULTS FOR OTHER BATTERY VOLTAGE RANGES

12 VDC: 27 – 33 VAC
24 VDC: 54 – 66 VAC

48 VDC: 110 – 130 VAC

WIRING DIAGRAM

L2115S90

Содержание LESTRONIC II

Страница 1: ...good performance and maximum cycle life CAUTION ALWAYS WEAR PROTECTIVE EYE SHIELDS AND CLOTHING WHEN WORKING WITH BATTERIES BATTERIES CONTAIN ACIDS WHICH CAN CAUSE BODILY HARM DO NOT PUT WRENCHES OR OTHER METAL OBJECTS ACROSS THE BATTERY TERMINAL OR BATTERY TOP ARCING OR EXPLOSION OF THE BATTERY CAN RESULT 1 When installing new batteries be sure the polarity of each battery and overall battery pac...

Страница 2: ... VOLTAGE IS APPROXIMATELY 650 VOLTS CAUTION ALWAYS UNPLUG THE ELECTRICAL PLUGS FROM THE AC OUTLET AND THE BATTERIES BEFORE ATTEMPTING ANY REPAIRS TO THE CHARGER WARNING DO NOT OPERATE THE CHARGER IF IT IS MALFUNCTIONING PERSONAL INJURY OR PROPERTY DAMAGE COULD RESULT The Lestronic II battery charger is a reliable automatic charger designed for long trouble free service If a malfunction should deve...

Страница 3: ...nsformer does not hum and the ammeter still does not register with the Electronic Timer Kit bypassed a continuity check of the charger AC circuit is necessary Disconnect the power supply cord from its outlet and the DC output connector from the battery connector and with a suitable continuity tester check the circuit across the power supply cord prongs With the Electronic Timer Kit bypassed the CI...

Страница 4: ...power supply cord from its outlet and the DC output connector from the battery connector and remove the charger cover 2 Disconnect the GREEN if included BLACK and RED wires of the Electronic Timer Kit Then remove the BLACK and WHITE leads of the power supply cord and both primary transformer coil leads from the Electronic Timer Kit terminal tabs The Kit can be removed by removing the three mountin...

Страница 5: ... READS 30 AMPS FOR MORE THAN 30 MINUTES This high output condition is caused by misuse connecting the charger to an incorrect battery system which is lower than what is rated for the charger A common error is to install one or more of the batteries in a battery pack reverse polarity Using a suitable DC voltmeter test to be sure all batteries in a battery pack are correctly wired and also test the ...

Страница 6: ...hen the batteries will not longer perform as required they should be replaced Part B Charger does not turn off New batteries with all good cells should rise to at least 2 5 volts per cell This will allow the finish charge rate to taper below 8 amperes As batteries age individual cells may weaken and these cells may not reach 2 5 volts This will result in finish charge rates greater than 8 amperes ...

Страница 7: ...ead so the wires do not break DANGER HIGH VOLTAGE WITH THE CHARGER OPERATING THE CHARGER CAPACITOR VOLTAGE IS APPROXIMATELY 650 VOLTS AC USE EXTREME CAUTION WHEN WORKING NEAR THE CAPACITOR TERMINALS In order to apply AC power directly to the transformer primary coil the Electronic Timer Kit must be bypassed Refer to Section 1 Part A for bypass procedures With the Electronic Timer Kit bypassed and ...

Страница 8: ...8 L2115S89 Transformer Coil Voltage Test 36 Volt Charger Without Capacitor Transformer Coil Voltage Test 36 Volt Charger With Capacitor TEST RESULTS FOR OTHER BATTERY VOLTAGE RANGES 12 VDC 27 33 VAC 24 VDC 54 66 VAC 48 VDC 110 130 VAC WIRING DIAGRAM L2115S90 ...