background image

Operating Instructions

5

01573C

the plates immediately upon discovery and
fill to the proper level with distilled water at
the completion of the very next charge cycle.
Battery capacity lost in this manner is
permanent and is not recovered with
additional charge cycles.

b.

Use of the equipment before the batteries
have been fully charged and the charger

turns off.  This shortens battery life and
hastens the onset of reduced daily range.
Battery capacity lost in this manner is
permanent and is not recovered with
additional charge cycles.

c.

This is the normal wear-out process for all
types of deep-cycle motive power batteries.

WIRING DIAGRAM

CAPACITOR

TRANSFORMER

CASE GROUND

RELAY

3

TIMER

ELECTRONIC

1

L2115B42

FUSE

ASSEMBLY

WITH DIODES

BUSHING

HEATSINK ASSEMBLY

2

1

2

3

4

G

R

E

E

N

WHITE

BLACK

TAN

TAN

TAN

TAN

B

L

A

C

K

B

L

A

C

K

BLACK

RED

TAN

TAN

R

E

D

BLACK

BUSHING

BL

AC

K

RED

DC NEG. (-)

DC POS. (+)

COMM

NC

WHITE

B

L

A

C

K

R

E

D

W

H

IT

E

LOCKOUT

RED

WH

ITE

INPUT

AC

Содержание 17670

Страница 1: ...EDUCE RISK OF INJURY CHARGE ONLY LIQUID ELECTROLYTE WET LEAD ACID RECHARGEABLE BATTERIES OTHER TYPES OF BATTERIES MAY BURST CAUSING PERSONAL INJURY OR DAMAGE 3 Do not expose charger to rain or snow 4 Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire electric shock or injury to persons 5 To reduce risk of damage to electric plug and cord p...

Страница 2: ...NSTRUCTIONS Charger should be grounded to reduce risk of electric shock Charger is equipped with an electric cord having an equipment grounding conductor The installed plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER NEVER ALTER AC CORD OR PLUG IF IT WILL NOT FIT OUTLET HAVE A PROPER OUTLET INSTALLED BY A QUALIFIED...

Страница 3: ... automatically when battery is fully charged Charge time varies with battery size and depth of discharge Allow 11 15 hours for normal charging Severely discharged batteries may require more time to be properly charged and equalized 6 After the charger has turned off disconnect the AC supply cord from outlet MAINTENANCE INSTRUCTIONS The battery charger requires minimal maintenance It should be kept...

Страница 4: ...harger is not plugged into a live AC outlet WARNING IF THE AC OR DC PLUG OR RECEPTACLE IS BROKEN TWISTED BENT OR LOOSE AND DOES NOT MAKE GOOD ELECTRICAL CONTACT HAVE IT REPLACED BY QUALIFIED SERVICE PERSONNEL IMMEDIATELY DO NOT USE THIS CHARGER IN THIS CONDITION AS FIRE OR PERSONAL INJURY CAN RESULT c DC fuses blown 2 CHARGER REMAINS AT HIGH RATE a The charger is connected to a battery pack with a...

Страница 5: ...s shortens battery life and hastens the onset of reduced daily range Battery capacity lost in this manner is permanent and is not recovered with additional charge cycles c This is the normal wear out process for all types of deep cycle motive power batteries WIRING DIAGRAM CAPACITOR TRANSFORMER CASE GROUND RELAY 3 TIMER ELECTRONIC 1 L2115B42 FUSE ASSEMBLY WITH DIODES BUSHING HEATSINK ASSEMBLY 2 1 ...

Страница 6: ...r factory and the expense of returning repaired or replaced items from the Lester factory to the owner will be paid for by the owner All warranty work accomplished at the Lester factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Leste...