output until they have been discharged a
number of times.

4.

Do not excessively discharge batteries.
Excessive discharge can cause polarity reversal
of individual cells resulting in complete failure
shortly thereafter.  Limited use of new batteries
will minimize the chance of cell reversal.

5.

Check the level of the electrolyte in conventional
liquid electrolyte lead acid batteries monthly.
Maintain the proper electrolyte level by adding
distilled or purified water when necessary.

Electrolyte levels lower during discharge and
rise during charge.  Therefore, it is mandatory
that water be added to cells only when they are
fully charged; do not overfill.  Old batteries
require more frequent additions of water than
new batteries.

6.

Keep tops of batteries clean and dry to prevent
excessive self-discharge. Keep battery terminals
reasonably tight..

Содержание 07210

Страница 1: ...tric shock or injury to persons 5 To reduce risk of damage to electric plug and cord pull by plug rather than cord when disconnecting charger 6 Make sure cord is located so that it will not be stepped on tripped over or otherwise subjected to damage or stress 7 An extension cord should not be used unless absolutely necessary Use of improper extension cord could result in a risk of fire and electri...

Страница 2: ...led and grounded in accordance with all electrical codes and ordinances DANGER NEVER ALTER AC CORD OR PLUG PROVIDED IF IT WILL NOT FIT OUTLET HAVE A PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN IMPROPER CONNECTION CAN RESULT IN A RISK OF ELECTRIC SHOCK This battery charger is for use on a nominal 120 volt circuit and has a grounding plug which looks like the adapter illustrated in Figure A A...

Страница 3: ...GING AND POSSIBLE DAMAGE TO BATTERIES WILL RESULT IF CHARGER SHOULD FAIL TO TURN OFF MAINTENANCE INSTRUCTIONS The battery charger requires minimal maintenance It should be kept clean and all connections are to be tightly secured In the event of intermittent operation examine and tighten if necessary all connections Be sure the chassis is securely grounded If any problems cannot be resolved consult...

Страница 4: ...evel of the electrolyte in conventional liquid electrolyte lead acid batteries monthly Maintain the proper electrolyte level by adding distilled or purified water when necessary Electrolyte levels lower during discharge and rise during charge Therefore it is mandatory that water be added to cells only when they are fully charged do not overfill Old batteries require more frequent additions of wate...

Страница 5: ...33S CORDSET AC 14 3 108 TWIST LOCK PLUG 33014S CORDSET AC 14 3 248 MOLDED PLUG 08512S CORDSET DC NO PLUG 12 2 99 14284S CORDSET DC NO PLUG 12 2 118 08807S CORDSET DC RING TERMINALS 96 14973S CORDSET DC MOLDED PLUG GRAY 103 08020S CORDSET DC LESTER PLUG 103 08607S CORDSET DC 50 AMP PLUG GRAY 56 10716S CORDSET DC 50 AMP PLUG GRAY 218 08224S CORDSET DC 175 AMP PLUG GRAY 101 10536S CORDSET DC EZ GO PL...

Страница 6: ...y to the owner will be paid for by the owner All warranty work accomplished at the Lester Electrical factory will be completed within a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Lester Electrical Warranty on parts not manufactured by Lester Electrical which ...

Отзывы: