LST-UME
EN
LESITE
Error Code
Description Measures
“Error T002”
“Error S002”
“CT:999 Err-T001”
“Error FANerr”
No thermocouple
detected
No heating element
detected
Thermocouple failure
in operation
Overheating
a.Check thermocouple connection
b.Replace thermocouple
a.Check heating element connection
b.Replace heating element
a.Check thermocouple connection
b.Replace thermocouple
a.Check hot air blower
b.Clean nozzle and filter
Error Code
Parts Replacement
● Replacement of heating element
● Replacement of Drive silica roller
Hot air nozzle fix screw
Hot air nozzle fix nut
Heating element
Unplug the thermocouple connector
,Loosen the four fixing screws of
nozzle. Then you can remove the
heating element after removing the
nozzle As shown on the right
Loosen Drive silica roller fixed screw ,
and then you can take down drive silica
roller ,As shown on the right