background image

LST-T004 Screen Data

LST-T004 Operations

04

LST-T004

LESITE

EN

537 N

18.0

mm

4 N

0.0

mm

MAX-F

MAX-L

Current-F

Current-L

1、The data below MAX-F is the maximum tensile force displayed by the broken 

    material in this test, which can be retained all the time.The unit of data is N 

    (can also be displayed in KGS, which can be switched by the unit switching (3)).
2、The data above MAX-L is the maximum walking distance displayed in this tensile 

    material test, which can be retained all the time. The unit of data is mm.

3、The data below Current-F is the current tensile data. The data unit is N (can also 
    be displayed in KGS, which can be switched by the unit switching (3)).
4、The data above Current-L is the current distance data. The unit of data is mm.

1、Open the cover of the tensiometer, take out the power cord, check whether the 

    power cord is in good condition, and connect to the power supply

2、Turn on the machine power switch(1).

3、Prepare base material samples for testing.

4、Use a screwdriver to loosen the 4 test sample compression screws (12) on the 

    movable plate(14), and then insert the prepared base material sample into both 

    sides of the machine respectively.

Содержание LST-T004

Страница 1: ...Tensiometer Manual Lesite Technology LESITE ...

Страница 2: ... as to avoid being hurted by the internal charged exposed power line or components In order to ensure the safety of users and reliable operation of tensiometer stabilized voltage power supply and leakage protector must be installed at the construction site Ensure that the protective earth connection is good The voltage rating stated on the tool must correspond with the line mains voltage AC220V Pl...

Страница 3: ...et 5 Confirm 6 Forward 7 Backward 8 Stop 1 2 3 Parameter LST T004 Keybord Model LST T004 Voltage Frequency Jaw spacing Tensile load Range Size L W H Net weight 230 V 50 Hz 5 300 mm max 2000 N max 100 mm 700 220 120 mm 12 Kg 02 KG N OK 4 5 6 7 8 LST T004 LESITE EN ...

Страница 4: ...LST T004 Main Parts 9 Keyboard 10 Fixed Slide Bar 11 Drive Shaft 12 Test Sample Compression Screw 13 Test Sample Platen 14 Movable Plate 15 Fixed Plate 9 10 11 12 13 14 15 03 LST T004 LESITE EN ...

Страница 5: ...the time The unit of data is mm 3 The data below Current F is the current tensile data The data unit is N can also be displayed in KGS which can be switched by the unit switching 3 4 The data above Current L is the current distance data The unit of data is mm 1 Open the cover of the tensiometer take out the power cord check whether the power cord is in good condition and connect to the power suppl...

Страница 6: ... run You can see that 4 lines of data change on the display screen When the base material sample is completely broken press the stop 8 button 7 After the test you can see the test data displayed on the display screen Please confirm whether the test sample is qualified according to the corresponding standard 8 Loosen the 4 test sample compression screws 12 and take out the base material sample if t...

Страница 7: ...warranty requirements The quality assurance does not include damage to wearing parts damage or defects caused by improper handling or maintenance and damage caused by falling products Irregular use and unauthorized modification should not be covered by the warranty It is strongly recommended to send the product to Lesite company or authorized repair center for professional inspection and repair On...

Страница 8: ...iometer 05 2022 EN FUZHOU LESITE PLASTICS WELDING TECHNOLOGY CO LTD Add 5 Jingpu Road Pushang Industry Park Cangshan Fuzhou 350007 Fujian China Tel 86 591 83818890 E mail info lesite com cn Web www lesiteweld com ...

Отзывы: