floor against the accidental fall of embers. In
order to achieve this goal, all joints of the floor
protection must be perfectly adjusted or filled
with grout. The floor protection may consist of:
a)
Slabs or tiles of stone (marble, granite,
slate, etc.) or ceramic at least 3/8" (10 mm)
thickness, secured in place;
b)
Bricks of concrete or terra-cotta, secured
in place;
c)
For a temporary floor protection, a sheet
metal of at least 0.015" (0,38 mm) thickness
or an incombustible composite cement board
of at least 3/8" (10 mm) thickness may be
used.
10.3 Protection under the pedestal:
The
floor protection must extend at least 6" (150 mm)
under the fireplace pedestal.
10.2 Removing the existing resilient flooring:
11.1 Pedestal installation:
Center the pedestal
Before beginning the installation of the floor
under the suspended hood. Level it using the 4
protection, remove any existing resilient flooring
leveling bolts built in the base.
(linoleum, carpet, etc.) in order to reach the wood
or concrete sub-flooring. The fireplace must not
rest on resilient flooring.
11. Fireplace pedestal installation
Extend the floor
protection at least 6"
(150 mm) under
the pedestal. The
opening for the
passage of
the outside air
intake duct
must be at
least 7" diameter
(180 mm)
Se
e p
ag
es
18
to
23
See pa
ges 18 t
o 23
DRAWING 10
Floor protection
extension under
the pedestal
Ash drawer
9000 Pedestal
(the 9120 pedestal
is pyramidal
without an
ash drawer)
Table
Wood basket
Grate
DRAWING 11
Pedestal assembly
Page 12
Bolts for
adjusting the
table height
REV. 2013-02