16. BBQ grill installation
17. Outside air intake installation
properly. Never install an outside air intake into a
garage, a non-ventilated or mechanically
ventilated attic or other inside room.
16.1 Fireplaces 5005, 7005, 7007, 7120:
Insert
the metal rod supplied with the BBQ into the
17.2 Dust type and diameter:
Use a 4" (100
holes pierced for this purpose, on both sides of
mm) I.D. aluminum flexible duct covered by a
the fireplace, at front
(Drawing 17).
fiberglass insulating jacket with an integrated
aluminum vapor barrier. The duct must be fixed
16.2 Fireplace 7100:
In order to support the
on the air intake collar at the back of the fireplace
grill, fix on each side of the wood basket, in front,
with screws and an adhesive aluminum tape.
the two supports supplied for this purpose. These
Always extend the duct up to the outside of the
supports are pre-drilled for the installation of the
building.
transverse metal rod that will maintain the BBQ.
grill at the desired height.
17.3 Sealing the vapor barrier:
Following the
piercing of the exterior wall for the passage of the
16.3 BBQ grill installation:
The BBQ grill is set
air intake duct, seal the flexible duct vapor barrier
in place by simply inserting the central long rod
jacket against the exterior wall vapor barrier.
into one of the holes provided on the hearth plate
This will prevent ice built up inside the wall. Use
at the back of the fireplace.
an adhesive aluminum tape.
17.4 Outside hood:
Complete the installation by
connecting the duct to the hood assembly. Fix the
hood on the wall and seal the joint with silicone.
The hood should be fitted with a screen.
17.1 IMPORTANT:
If the building is too
airtight or if a negative pressure inside the
building is susceptible to harming the chimney
draft, the optional outside air intake
(Drawing 18)
must be installed to ensure the fireplace works
Page 15
Fireplaces 5005, 7005, 7007, 7120:
BBQ grill mounting
BBQ Grill
Support Metal Rod
DRAWING 17
Outside air intake (optional)
DRAWING 18
Heat shield
ATTENTION: The air intake
collar is always located
on the left side of the
fireplace but the
pull handle is
on the right side.
5,
5"
(
14
0
m
m
)
Pull
Handle
Air Intake
16
"
(
40
6
m
m
)
4" I.D. (100 mm)
REV. 2013-05