background image

Installation, Operation 

and Maintenance Manual

LES FOYERS

FIREPLACES

DON-BAR

OPEN FIREPLACES

Les foyers DON-BAR Fireplaces, inc.

Shop and Showroom:  741, St-Vallier Ouest, Quebec (Quebec) G1N 1E2

Phone:  (418) 686-9114 -  Fax: (418) 686-9117

Website:  www.don-bar.com  -  Email:  [email protected]

7120

7120

7100

7100

5005

5005

7005

7005

7007

7007

REV.  2013-05

Содержание 5005

Страница 1: ...S DON BAR OPEN FIREPLACES Les foyers DON BAR Fireplaces inc Shop and Showroom 741 St Vallier Ouest Quebec Quebec G1N 1E2 Phone 418 686 9114 Fax 418 686 9117 Website www don bar com Email don bar don bar com 7120 7120 7100 7100 5005 5005 7005 7005 7007 7007 REV 2013 05 ...

Страница 2: ... designed to be connected to air ventilated factory built chimneys chimney without insulation KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE USE THE 7000 SERIES FIREPLACES MEET THE REQUIREMENTS OF ULC S627 Space Heater for use with Solid Fuel 2000 EPA Certified EPA Exempt This document in its entirety is the intellectual property of Les Foyers Don Bar inc Any unauthorized use will expose its author o...

Страница 3: ...4 2 Fireplace 7100 Hearth plate installation 5 3 Wall bracket height and aligment 14 3 Installation of the optional decorative finish on 5 4 Anchoring the wall support bracket the 7100 table 6 Types of installations 15 Firescreen installation 6 1 Chimney outlets 15 1 Fireplaces 5005 7005 7007 7120 15 2 Fireplace 7100 7 Chimney Wall outlet 7 1 Height of the chimney wall outlet 16 BBQ grill installa...

Страница 4: ...fessional fireplace fitter for the installation 1 4 Before lighting your first fire read the instructions of Part 2 regarding operating the fireplace 1 5 Your fireplace produces heat and provides great ambiance but it should not be used as the main source of heating 2 1 Approved chimneys Your Don Bar fireplace is designed to be installed with any 8 I D 200 mm masonry or prefabricated chimney beari...

Страница 5: ... the required 2 50 mm air space a minimum 14 355 mm free continuous path is required to install the chimney If the fireplace has a ceiling outlet it is usually easier to install the fireplace first then the chimney Do not connect this fireplace to a chimney connected to another heating device 3 3 Chimney minimum height 15 feet 4600 mm This length is measured from the floor where the fireplace is i...

Страница 6: ...wn in Drawing 4 4 3 Exterior walls Install the three 2 x 8 pieces specified in article 4 2 then place a 3 4 18 mm thick plywood over them The plywood should be flush with the wall furring The objective is to build a solid backing to anchor the wall support bracket 5 1 Regular wall support bracket Drawing 5 The fireplace is shipped with a wall support bracket in the form of an inverted T When insta...

Страница 7: ...o ensure a fitted connection with the fireplace chimney sleeve Center the bracket on the chimney if the chimney is already installed 5 4 Anchoring the wall support bracket The wall support bracket must be firmly anchored to the rear wall because the fireplace rests on it If you have a wood framed wall fix the bracket with long bolts Use metal expansion nuts and bolts to anchor the bracket against ...

Страница 8: ...the wall verify that the 7 1 Height of the chimney wall outlet chimney is centered on the wall support bracket 1 Fireplaces 7007 7100 7120 In order for the top of the fireplace hood to touch the ceiling measure the distance between the top Page 8 DRAWING 6 Chimney Wall outlet Fireplaces 7007 7100 7120 Fireplaces 5005 7005 8 200 mm 4 100 mm Standard height under the finished ceiling 16 400 mm Manda...

Страница 9: ... beyond the dimensions of 2 Incombustible wall If you are working the ceiling adaptor If the chimney must be with a 100 incombustible wall like a installed before the fireplace it must project 1 2 co nc re te fo un da ti on wa ll wi th ou t a 12 mm below the finished ceiling The ceiling combustible finish drill a hole of a diameter adaptor has 4 holes for its fixation against the sufficient to all...

Страница 10: ...nd conceal the joint between the ceiling and the cathedral adaptor 9 3 Rigid rockwool insulation Install the rigid insulation pads that are supplied with the fireplace inside the cathedral adaptor Do not completely fill the cathedral adaptor with the insulation There must always be at least 2 50 mm free for air space between the insulation and the chimney 10 1 Listed parts For the installation of ...

Страница 11: ...flashing 10 10 Roof braces Any chimney that extends 11 2 Heat shield Before installing the fireplace more than 6 feet 2 m above the roof needs to be on its wall support bracket mount the heat shield laterally strengthened with a pair of telescopic on the back of the fireplace if it has not already roof braces been installed by the manufacturer Begin the installation by fixing the bolt at the top o...

Страница 12: ...incombustible protection must be placed underneath and extend around the fireplace this includes under the pedestal of the 7100 Fireplace This protects the floor against the accidental fall of embers In order to achieve this goal all joints of the floor protection must be perfectly adjusted or filled with grout The floor protection must extend at least 18 460 mm in front of the fireplace opening a...

Страница 13: ... fireplace pedestal as shown Drawing 14 Center the fireplace pedestal under the hood Complete the installation by putting the table the wood basket and the log grate as illustrated These parts are simply placed with no particular fastening Finish the installation by slipping the ash drawer into its slot on the pedestal Leave a space of about 2 50 mm between the top of the table and the bottom of t...

Страница 14: ...ned by an S fastener at the bottom of the glass and two others on the upper side of the glass Drawing no 16 The bottom S fastener is clipped on the edge of the wood basket Those of the top are retained by a fold inside the hood Contrary to the ceramic glass firescreen the S fasteners of the metal firescreen are already soldered in the place on the firescreen frame Small black metallic triangles ar...

Страница 15: ... barrier Following the piercing of the exterior wall for the passage of the 16 3 BBQ grill installation The BBQ grill is set air intake duct seal the flexible duct vapor barrier in place by simply inserting the central long rod jacket against the exterior wall vapor barrier into one of the holes provided on the hearth plate This will prevent ice built up inside the wall Use at the back of the fire...

Страница 16: ... 5005 3 75 mm 23 584 mm 24 5 620 mm 34 850 mm 31 787 mm wall 29 75 755 mm 42 1070 mm C With ventilated wall heat shields C 22 5 570 mm 36 915 mm 36 915 mm 3 2 8 1 0 m m 37 940 mm REQUIRED CLEARANCES Without wall heat shields Incombustible ventilated heat shields 50 high 1270 mm Page 16 REV 2013 05 ...

Страница 17: ...mm 42 1070 mm 29 75 755 mm 40 1015 mm 37 940 mm 22 5 570 mm 36 915 mm 36 915 mm 3 2 8 1 0 m m chimney Floor proctection wall With ventilated wall heat shields REQUIRED CLEARANCES Without wall heat shields Incombustible ventilated heat shields 50 high 1270 mm Page 17 7005 33 838 mm REV 2013 05 ...

Страница 18: ...8 1210 mm 42 1070 mm 29 75 755 mm 40 1015 mm 37 940 mm 22 5 570 mm 36 915 mm 36 915 mm 3 2 8 1 0 m m chimney Floor proctection With ventilated wall heat shields REQUIRED CLEARANCES Without wall heat shields Incombustible ventilated heat shields 50 high 1270 mm wall Page 18 7007 8 203 mm C 8 203 mm C REV 2013 05 53 1 4 1350 mm ...

Страница 19: ...915 mm 5 0 1 2 7 0 m m chimney made to measure Ceiling outlet Wall outlet chimney Floor proctection With ventilated wall heat shields REQUIRED CLEARANCES Without wall heat shields Incombustible ventilated heat shields 50 high 1270 mm wall Page 19 7100 8 200 mm 18 450 mm C 72 1830 mm 51 1295 mm 8 203 mm C 8 203 mm C REV 2013 05 53 1 4 1350 mm 30 1 4 768 mm ...

Страница 20: ... mm 30 762 mm 42 1065 mm 42 1065 mm 4 2 1 0 6 5 m m chimney made to measure Ceiling outlet Wall outlet chimney Floor proctection With ventilated wall heat shields REQUIRED CLEARANCES Without wall heat shields Incombustible ventilated heat shields 50 high 1270 mm wall Page 20 7120 8 203 mm C 8 203 mm C REV 2013 05 53 1 4 1350 mm ...

Страница 21: ... 3 The fire 6 1 Glass maintenance 3 1 Opening the chimney flue damper 6 2 Replacing a broken glass pane 3 2 Adjusting the chimney flue damper 3 3 How to start a fire 3 4 Firescreen is mandatory 7 Chimney maintenance 3 5 Preventing overfiring 7 1 Creosote build up and removing 3 6 Forbidden flammable liquids 7 2 Inspection and regular maintenance 3 7 Smoke release during the first fire 7 3 Soot bui...

Страница 22: ... create smoke returns Don Bar Fireplaces cannot guarantee the absence of smoke returns but if this phenomenon occurs special attention should be given to the following situations mechanical ventilators in operation kitchen hood dryer air heating system air exchanger drafts room or house negative pressure inadequate chimney height exterior structures harmful to the chimney draft or capable of causi...

Страница 23: ... To open it just turn the handle 3 8 Caution Very hot Your fireplace can 3 2 Adjusting the chimney flue damper At the become very hot Be careful when coming close beginning the damper must be completely open to it Keep clothes furniture drapes pets and Later following the formation of embers the young children away from the fireplace flame will be less intense the chimney flue warmer and you will ...

Страница 24: ...aint finish Normal maintenance wood burns slowly tar and organic vapors are requires only a simple dusting using a dry and released These combustion by products combine soft duster or a feather duster Avoid splashing with moisture to form creosote When creosote liquids on the fireplace vapor comes in contact with a relatively cold surface such as a chimney flue during a slow 5 2 Repainting If over...

Страница 25: ...ild up eventually dripping into the fireplace In extreme cases the condensation water can even infiltrate the chimney insulation To avoid these problems it is necessary to maintain an acceptable humidity level inside the house This relative humidity level is between 30 and 35 during winter To learn more about the possible techniques to solve a moisture problem you can consult free of charge the gu...

Страница 26: ...r Bolt 7 180 mm nut and washer for the central hearth plate Refractories for the hearth bottom 2 Steel mesh firescreen Left triangular ceramic glass firescreen 5 mm Right triangular ceramic glass firescreen 5 mm Steel S fastener for the glass firesreen bottom Steel S fastener for the glass firescreen top Steel mesh triangular firescreen left side Steel mesh triangular firescreen right side Opaque ...

Страница 27: ...e don t reuse your fireplace firewood until a professional has inspected it A chimney fire Don t let creosote built up in the chimney can overheat the chimney components wrap it Don t burn coniferous construction wastes inside curve crack or dislocate certain components or materials containing glues paints or other chemicals Do all the recommendations of the professional Always have a fire extingu...

Страница 28: ...egarded as normal damages to the building following the 10 Thewarrantydoesnotcover maintenance However all the repair or the replacement of any part original parts shipped with the 10 1 Brokenglass coveredbythewarranty fireplace are warranted against 10 2 Damages caused by a material or workmanship defects for chimneyfire 4 No representative employee or agent 1 year following the date of 10 3 Ship...