background image

7

LEROY-SOMER

InstallatIon and maIntenance

LSA 40 - 4 POLES

ALTERNATORS

4455 en - 10.2009 / a

Connection code

 L.L voltage

Factory connection 

L1(U)

N

L3(W)

T1

T7

T12

T10

T4

T9

T3

T6

T11

T5

T2

T8

L2(V)

A

3 phases

3 phases

Winding

60 Hz

50 Hz

190 - 208

190 - 240

220 - 230

      -

    -

190 - 208

6

7

8

N

T1

T7

T12

T10

T4

T9

T3

T6

T11

T5

T2

T8

L1(U)

L3(W)

L2(V)

D

F

L1(U)

M

L3(W)

T1

T7

T12

T10

T4

T9

T3

T6

T11

T5

T2

T8

L2(V)

Tension LM = 1/2 tension  LL

LM voltage  = 1/2 LL voltage

R 220 voltage sensing: 

   0  => (T8)  /  110 V => (T11)

R 438 voltage sensing: 

   0  => (T3)  /  220 V => (T2) 

N

L1(U)

L2(V)

L3(W)

NDE 

T9

T8

T7

T12
T10

T11

T4

T3

T2

T1

T5

T6

Winding

60 Hz

50 Hz

380 - 415

380 - 480

440 - 460

      -

    -

380 - 416

6

7

8

R 220 voltage sensing: 

   0  => (T8)  /  110 V => (T11)

R 438 voltage sensing: 

   0  => (T3)  /  380 V => (T2) 

NDE 

N

L1(U)

L2(V)

L3(W)

L1(U)

L2(V)

L3(W)

T9

T8

T7

T12
T10

T11

T4

T3

T2

T1

T5

T6

1 phase

1 phase
or
3 phases

FF

Winding

60 Hz

50 Hz

220 - 240

220 - 240

220 - 240

200

250 - 260

      -

6

7

8

R 220 voltage sensing: 

   0  => (T1)  /  110 V => (T4)

R 438 voltage sensing: 

   0  => (T8)  /  220 V => (T11) 

NDE 

M

L

L

L

L

T9

T8

T7

T12

T10

T11

T4

T3

T2

T1

T5

T6

Winding

60 Hz

50 Hz

220 - 240

220 - 240

220 - 240

200

250 - 260

      -

6

7

8

NDE 

T9

T8

T7

T12

T10

T11

T4

T3

T2

T1

T5

T6

L

L

L

T1

T7

T12

T10

T4

T9

T3

T6

T11

T5

T2

T8

L

M

Tension LM = 1/2 tension  LL

LM voltage  = 1/2 LL voltage

R 220 voltage sensing: 

  0  => (T8)  /  110 V => (T11)

R 438 voltage sensing: 

   0  => (T3)  /  220 V => (T2) 

Physical and visual checks

3.2.1 - 

Before starting the machine for the first time, check that:

- the fixing bolts on the feet are tight

- the cooling air is drawn in freely

- the protective louvres and housing are correctly in place

- the standard direction of rotation is clockwise as seen from 

the  shaft  end  (phase  rotation  in  order  1  -  2  -  3).  For  anti-

clockwise rotation, swap 2 and 3.

-  the  winding  connection  corresponds  to  the  site  operating 

voltage (see section § 3.3).

Terminal connection diagrams

3.3 - 

To modify the connection, change the position of the terminal 

cables. The  winding code is specified on the nameplate.

Any intervention on the alternator terminals during 

reconnection or checks should be performed with 

the machine stopped.

Содержание LSA 40-4 POLE

Страница 1: ...33 33 37 30 30 15 4 322 324 323 343 1 41 124 120 198 100 70 S A E 5 2009 10 a This manual must be supplied to the end user LSA 40 4 POLE ALTERNATORS Installation and maintenance 4455 en...

Страница 2: ...general danger to personnel Warning symbol for electrical danger to personnel Note LEROY SOMER reserves the right to modify the characteristicsofitsproductsatanytimeinordertoincorporate the latest tec...

Страница 3: ...SERVICE 3 1 Montage 6 3 2 Contr les avant mise en service 6 3 3 Sch mas de couplage des bornes 7 3 4 Mise en service 9 3 5 R glages 9 4 ENTRETIEN MAINTENANCE 4 1 Mesures de s curit 10 4 2 Maintenance...

Страница 4: ...frame Make sure that the nameplate on the machine conforms to your order The machine name is defined according to various criteria see below Example of description for LSA 40 S4 J6 4 LSA name used in...

Страница 5: ...andard feet and SAE flanges coupling discs B 34 two bearing with SAE flange and standard cylindrical shaft extension Drip proof machine self cooled Options 2 2 1 Protection against harsh environmentsh...

Страница 6: ...mm WARNING This alternator has been balanced with a 1 2 key Location 3 1 3 Ensure that the ambient temperature in the room where the alternator is placed cannot exceed 40 C for standard power ratings...

Страница 7: ...110 V T4 R 438 voltage sensing 0 T8 220 V T11 NDE M L L L L T9 T8 T7 T12 T10 T11 T4 T3 T2 T1 T5 T6 Winding 60 Hz 50 Hz 220 240 220 240 220 240 200 250 260 6 7 8 NDE T9 T8 T7 T12 T10 T11 T4 T3 T2 T1 T5...

Страница 8: ...220 240 250 260 200 220 240 6 7 8 R 220 voltage sensing 0 T8 110 V T11 R 438 voltage sensing 0 T3 220 V T2 M L L NDE T9 T8 T7 T12 T10 T11 T4 T3 T2 T1 T5 T6 1 phase or 3 phases L1 U L2 V L3 W L L Windi...

Страница 9: ...n in the terminal connection diagrams theequipotentialearth links have been implemented correctly cross section and continuity of the earths Commissioning 3 4 The alternator can only be started up and...

Страница 10: ...any alkaline products Certain strictly defined pure volatile degreasing products can be used such as Normal petrol without additives inflammable Toluene slightly toxic inflammable Benzene or benzine...

Страница 11: ...tage does not reach the rated value when the battery is removed Check the connection of the voltage reference to the AVR Faulty diode Armature short circuit The alternator builds up but its voltage di...

Страница 12: ...A Connect a 12 V battery in series with a rheostat of approximately 50 ohms 300 W and a diode on both field wires 5 and 6 Assembly B Connect a Variac variable power supply and a diode bridge on both...

Страница 13: ...ncing bolt M5 4 N m Disc shaft screw M10 66 N m Guard screws M5 4 N m Cover screws M5 3 6 N m The screws for fixing the feet on the housing and immobilising the stator must not be removed bolt of the...

Страница 14: ...e whole alternator is correctly assembled and that all screws are fully tightened Accessing the main field and stator 4 6 7 Dismantling 4 6 7 1 Follow the procedure for dismantling bearings see sectio...

Страница 15: ...field LSA 40 VS1 VS2 S3 S4 M5 L7 No load 0 9 0 8 0 8 0 8 0 8 0 8 At rated load 2 1 2 1 2 2 2 2 2 1 2 1 Three phase 4 pole AREP excitation 4 7 2 Resistances at 20 C W LSA 40 VS1 VS2 S3 S4 M5 L7 L N st...

Страница 16: ...rts list Our extensive network of service stations can dispatch the necessary parts without delay To ensure correct operation and the safety of our alternators we recommend the use of original manufac...

Страница 17: ...iption 1 1 Stator assembly 100 1 Exciter armature 4 1 Rotor assembly 120 1 Terminal plate support 15 1 Fan 124 1 Terminal plate 28 1 Earth terminal 198 1 Regulator AVR 30 1 DE flange 322 1 Coupling di...

Страница 18: ...bly 91 4 Field fixing screw 4 1 Rotor assembly 100 1 Exciter armature 15 1 Fan 120 1 Terminal plate support 28 1 Earth terminal 124 1 Terminal plate 30 1 DE shield 132 1 Terminal box 33 1 Air outlet g...

Страница 19: ...rocating internal combustion engine driven alternating current generating sets Part 3 Alternating current generators for generating sets The Low Voltage Directive Nr 2006 95 CE dated 12 December 2006...

Страница 20: ......

Отзывы: