DIGIDRIVE SK

Getting started guide

This man

ual is to be given to

the end user

T1

T2

T3

T4

0V

Remote current speed
reference input (A1)

+10V reference output

Local voltage speed 
reference input (A2)

B1

B2

B3

B4

B5

B6

B7

+24V output

Drive Enable/Reset
(USA: Not stop)

Run Forward
(USA: Run)

Run Reverse
(USA: Jog)

Local (A2)/Remote (A1)
speed reference select

Remote speed
reference input

V

_

+

10k

(2kmin)

+24V

0V

EUR

Analog output 
(motor speed)

Digital output 
(zero speed)

Содержание DIGIDRIVE SK

Страница 1: ...reference input A1 10V reference output Local voltage speed reference input A2 B1 B2 B3 B4 B5 B6 B7 24V output Drive Enable Reset USA Not stop Run Forward USA Run Run Reverse USA Jog Local A2 Remote...

Страница 2: ...ntal impacts of its manufacturing operations and of its products throughout their life cycle To this end we operate an Environmental Management System EMS which is certified to the International Stand...

Страница 3: ...trol terminals I O specification 15 5 Keypad and Display 18 5 1 Programming keys 18 5 2 Control keys 18 5 3 Selecting and changing parameters 19 5 4 Saving parameters 20 5 5 Parameter access 20 5 6 Se...

Страница 4: ...4 Digidrive SK Getting Started Guide www leroy somer com Issue Number d Notes...

Страница 5: ...personnel They do not isolate dangerous voltages from the output of the drive or from any external option unit The supply must be disconnected by an approved electrical isolation device before gainin...

Страница 6: ...uction motors are designed for single speed operation If it is intended to use the capability of a drive to run a motor at speeds above its designed maximum it is strongly recommended that the manufac...

Страница 7: ...t the capacitors may fail to discharge or be prevented from being discharged by a voltage applied to the output terminals If the drive has failed in a manner that causes the display to go blank immedi...

Страница 8: ...g 3 0 Ib 2ML B SKB1100110 1 1 1 5 32 24 0 5 2 7 8 28 Model Size CT reference Nominal motor power Input fuse rating Typical full load input current 100 RMS output current 150 overload current for 60s M...

Страница 9: ...3400037 0 37 0 5 6 1 7 2 5 1 3 1 95 100 1 2 kg 2 7 Ib 1 2T B SKB3400055 0 55 0 75 6 2 5 3 1 1 7 2 55 100 1 5T B SKB3400075 0 75 1 0 6 3 1 3 75 2 1 3 15 100 2T B SKB3400110 1 1 1 5 6 4 0 4 6 2 8 4 2 10...

Страница 10: ...C D E F G H I mm in mm in mm in mm in mm in mm in mm in mm in mm in A 140 5 51 154 6 06 11 0 43 64 2 52 75 2 95 145 5 71 104 4 09 143 5 63 B 190 7 48 205 8 07 10 9 0 43 65 9 2 6 85 3 35 77 3 0 156 6...

Страница 11: ...This is the minimum spacing between drives at the base of the drive where it is mounted against a back plate Figure 3 3 Features of the drive size B illustrated Drive size A B C mm in mm in mm in A 10...

Страница 12: ...upply Optional Thermal protection device Stop Start Reset PE Supply ground Internal EMC filter Optional EMC filter Optional ground connection Supply ground Optional EMC filter Optional line reactor Fu...

Страница 13: ...C at 230V 50Hz proportional to supply voltage and frequency The drive must be grounded by a conductor sufficient to carry the prospective fault current in the event of a fault See also the warning in...

Страница 14: ...mains supply Where the motor cable is short it permits the requirements of EN61800 3 to be met for the second environment For longer motor cables the filter continues to provide a useful reduction in...

Страница 15: ...tended EMC filter disconnected A The control circuits are isolated from the power circuits in the drive by basic insulation single insulation only The installer must ensure that the external control c...

Страница 16: ...V mA as parameter range Parameter range 4 20 20 4 0 20 20 0 4 20 20 4 VoLt Scaling Input range automatically scaled to Pr 01 Minimum set speed Pr 02 Maximum set speed Input impedance 200 current 100k...

Страница 17: ...trip where they become edge triggered See and above If the enable and run forward or enable and run reverse terminals are closed when the drive is powered up the drive will run straight away up to a...

Страница 18: ...d 5 1 Programming keys The MODE key is used to change the mode of operation of the drive The UP and DOWN keys are used to select parameters and edit their values In keypad mode they are used to increa...

Страница 19: ...and display flashes the value in the parameter being shown in the left hand display Pressing the MODE key in parameter edit mode will return the drive to the parameter view mode If the MODE key is pre...

Страница 20: ...he output bridge is inactive Drive inhibited The drive is inhibited because there is no enable command or a coast to stop is in progress or the drive is inhibited during a trip reset Drive has tripped...

Страница 21: ...er a security code has been set into Pr 25 5 6 2 Unlocking a security code Select parameter to be edited Press the MODE key the right hand display will flash CodE Press the UP key to start entering th...

Страница 22: ...1 Parameter descriptions Level 1 Used to set the minimum speed at which the motor will run in both directions 0V reference or minimum scale current input represents the value in Pr 01 Used to set the...

Страница 23: ...o Pr 05 is set by pressing the MODE key on exit from parameter edit mode The drive must be disabled stopped or tripped for a change to take place If Pr 05 is changed while the drive is running when th...

Страница 24: ...0V Eur Analogue output motor speed Digital output zero speed Reference select Reference select 10k 2kmin T1 T2 T3 T4 B1 B2 B3 B4 B5 B6 B7 T4 B7 Reference selected 0 0 A1 0 1 Preset 2 1 0 Preset 3 1 1...

Страница 25: ...verse V _ 24V 0V Eur Analogue output motor speed Digital output zero speed Not used Not used Not used Not used T1 T2 T3 T4 B1 B2 B3 B4 B5 B6 B7 0V 10V reference output 24V output Drive Enable Reset US...

Страница 26: ...maximum speed Pr 02 20 WARNING 95 94 T4 T2 x 1 0 1 63 Invert 61 P Gain 62 I Gain PID reference input PID feedback input B7 PID enable Drive healthy 64 PID high limit 65 PID low limit 66 81 Drive refe...

Страница 27: ...to 95 can be accessed LoC Used to lock a security code in the drive See section 5 6 Security codes on page 21 for further details No Function Range Defaults Type 06 Motor rated current 0 to Drive rat...

Страница 28: ...e Yes 2 Enable Run Forward Reverse No 3 Stop Run Forward Reverse Yes 4 Stop Run Jog Yes 5 User programmable Run Forward Run Reverse No 6 User Programmable User Programmable User Programmable User Prog...

Страница 29: ...SP Motor speed in rpm Cd Machine speed in customer defined units See Pr 24 Multiplying factor on motor speed rpm to give customer defined units Used to set up a user security code See section 5 6 Sec...

Страница 30: ...by using Prog mode otherwise the drive will trip on C Acc at power up When boot mode is enabled it is impossible to return to rEAd or Prog mode To disable this mode please get in touch with your usual...

Страница 31: ...age to frequency ratio constant torque standard load On Voltage to frequency ratio dependant on load current dynamic variable torque load This gives a higher motor efficiency 0 Disabled 1 Detect posit...

Страница 32: ...ctionality of terminal B7 as set up with Pr 05 drive configuration will be disabled When setting to th press mode four times Analogue reference 2 will no longer be selected as the speed reference NOTE...

Страница 33: ...Type 38 Autotune 0 to 2 0 RW When a rotating autotune is selected the drive will accelerate the motor up to 2 3 maximum speed in Pr 02 WARNING The motor must be at a standstill before a non rotating...

Страница 34: ...rive has been commanded to stop the brake is applied immediately Defines the time between the frequency and load condition being met and the brake being released The ramp is held during this time Defi...

Страница 35: ...hreshold 46 47 _ Motor frequency Brake release frequency Brake apply frequency 48 49 _ _ Reference enabled Latch Drive active In Out Reset Pre brake release delay 50 Post brake release delay 51 Brake...

Страница 36: ...no PLC ladder program 1 LogicStick is fitted PLC ladder program is installed but stopped 2 LogicStick is fitted PLC ladder program is installed and running 3 LogicStick is not fitted Pr 61 to Pr 70 a...

Страница 37: ...lowing read only RO parameters can be used as an aid to fault diagnosis on the drive See Figure 8 1 Diagnostics logic diagram on page 44 No Function Range Defaults Type 71 to Pr 61 to Pr 70 set up 0 t...

Страница 38: ...e input A1 10V reference output Local voltage speed reference input A2 24V output Drive Enable Reset Run Forward Run Reverse Local A2 Remote A1 speed reference select 10k 2kmin Eur USA Analogue output...

Страница 39: ...ot a standard 50 60Hz motor set Pr 39 accordingly Ready to autotune Enable and run the drive Close The Enable and Run Forward or Run Reverse signals Autotune The Digidrive SK will carry out a non rota...

Страница 40: ...required control terminal connections 0V 10V reference output 24V output Drive Enable Reset Forward Reverse Analogue output motor speed Digital output zero speed Not used Not used Not used Not used T1...

Страница 41: ...tor in Pr 09 If the motor is not a standard 50 60Hz motor set Pr 39 accordingly Ready to autotune Enable and run the drive Close The enable signal Press the START key Autotune The Digidrive SK will ca...

Страница 42: ...d on drives heatsink Heatsink temperature exceeds allowable maximum th Motor thermistor trip Excessive motor temperature O Ld1 User 24V or digital output overload Excessive load or short circuit on 24...

Страница 43: ...rring parameters SmartStick or when changing the default settings The drive is running or enabled Repeat the procedure with the drive locked Trip code Condition Possible cause Drive voltage rating UV...

Страница 44: ...84 DC bus voltage 42 41 40 39 38 37 32 09 08 07 06 Motor rated current Motor rated speed Motor rated voltage Motor power factor Dynamic V to f select Switching frequency Autotune Motor rated frequency...

Страница 45: ...eNet SM CANopen SM INTERBUS SM Ethernet SM Keypad Plus Remote panel mounting LCD multilingual text keypad display to IP54 NEMA 12 with additional help key SK Keypad Remote Remote panel mounting LED di...

Страница 46: ...all of the drive s advanced parameters and also on the serial communications Furthermore it gives set up examples for the drive Option Module User Guides Installation Sheets These guides provide detai...

Страница 47: ...13 Not used 14 15 Jog reference Hz 1 5 16 Analogue input 1 mode mA 4 20 17 Enable negative preset speeds OFF 18 Preset speed 1 Hz 0 0 19 Preset speed 2 Hz 0 0 20 Preset speed 3 Hz 0 0 21 Preset speed...

Страница 48: ...67 Configurable parameter 7 68 Configurable parameter 8 69 Configurable parameter 9 70 Configurable parameter 10 Level 3 parameters 71 Pr 61 set up parameter 72 Pr 62 set up parameter 73 Pr 63 set up...

Страница 49: ...ast acting fuses e g Bussman Limitron KTK series Gould Amp Trap ATM series or equivalent are used in the AC supply 11 2 AC supply specification The drive is suitable for use in a circuit capable of de...

Страница 50: ...2kmin 24V 0V Pr 29 Eur Analogue output motor speed Digital output zero speed T5 T6 OK Fault T1 T2 T3 T4 0V Remote current speed reference input A1 10V reference output Local voltage speed reference i...

Отзывы: