7) Service

Service policy

The LD360 DMX is designed for a long, trouble free life. If you suspect that you have a
dimmer problem, the first step is to check all other system components and connections.
The easiest test is to substitute a known good dimmer in place of the suspected unit.
Make sure that the DMX start address is set to the same value.

Specific problems and solutions are listed below:

Problem

Indication

Solution

   no power

  breaker not lighted

 check incoming power

  No response to DMX

 Display shows D, but
no output

  Level set in Channel menu
Clear dimmer and recheck.

   Shorted load

  breaker trips

  repair instrument or cable

   No DMX signal

  Display shows A

 Check cable and controller

   SCR failure

  Channel stuck at full

  refer to service center

  Over Temp

 Error 02

  Check airflow

  Over Voltage

 Error 01

  Check power wiring

  Overload

  breaker trips

   check wattage of loads

If a problem is verified in the dimmer pack, contact your Leprecon dealer for service.
Because of the high voltages present inside of the dimmer, it is important that all service
be done only by qualified personnel. Substandard repairs can create a dangerous
condition.

Warranty Information

For a period of two years from the date of sale, Leprecon LLC will replace any defective
parts and will repair any defective module returned to the factory prepaid, without charge
for parts or labor.  Damage caused by misuse,  incorrect line voltage or connection to
shorted loads is not covered under warrany.
Please consult your dealer for full warranty details.

The Leprecon service department may be reached at 810-231-9373 during business
hours, or a message may be left after hours.  Our fax number is 810-231-1631.

Our service department must first authorize any return to the factory.  Do not return any
equipment without calling for an authorization number.

Содержание ULD-360

Страница 1: ...2005 2008 All rights reserved Publication 21 1046 Rev A This document is the property of Leprecon LLC and is provided for service and instructional purposes only Possession does not imply or convey r...

Страница 2: ...Temperature 4 Power Capacity 4 Control input 5 3 Optional Wireless DMX 6 3 Installation 8 Mounting 8 Power Connection 8 Load Connection 8 4 Turning on Power 8 5 Front Panel Controls 9 Resetting the U...

Страница 3: ...3 Endplate Illustration ULD 360DMX HP Menu Enter Data In ULD Series Line A Line B Data Out ON I O OFF ON I O OFF d 0 0 DMX Out DMX In LED display Breaker A...

Страница 4: ...ating florescent fixtures see the section regarding Front Panel Controls 2 Specifications Power Connection Unless otherwise indicated your ULD 360 dimmer is designed for connection to standard US powe...

Страница 5: ...d and acceptable cable see the Appendix at the end of this manual For convenience DMX in and out connectors are provided on the ULD 360DMX This allows easy connection to additional dimmer packs The DM...

Страница 6: ...al receiver card and power supply External antenna Switch and LED indicator for setting the communication link Background Information The W DMX system uses a 2 4 ghz radio signal to transmit DMX data...

Страница 7: ...down for four seconds The LED will turn off indicating that the link has been broken To establish a link to a specific transmitter 1 Unlink the dimmer by pressing and holding the switch as described a...

Страница 8: ...protected by a properly sized circuit breaker If you have any questions about the suitability of the power circuit that you intend to use with the LD360 dimmer consult with a qualified electrician Lo...

Страница 9: ...y depressing and holding the ENTER switch while turning on the first breaker Address Menu When the dimmer is first turned on the display shows the starting channel address of the ULD 360 This is the D...

Страница 10: ...control channel 2 and so on for all of the circuits in the pack If you have multiple ULD dimmers generally the first dimmer will be set to start address 001 Assuming that each dimmer has six circuits...

Страница 11: ...olon will blink to indicate new data has been entered Press the ENTER key saves the change and advance to the next channel The ULD 360 returns to the Address Menu automatically after 4 seconds if no k...

Страница 12: ...ing from Channel 1 to Channel 6 then automatically cycle back to channel 1 This automatic cycling is indicated by the flashing colon The Status Mode first displays the current input state of the dimme...

Страница 13: ...o and manual cycle modes In manual mode the menu steps through its displays when the UP or DOWN keys are pressed The colon is steady in manual mode If a channel has been set to a fixed level in the Ch...

Страница 14: ...or conditions The ULD 360 will protect itself if the line voltage or operating temperature exceeds safe limits In these cases the dimmer will turn off all channels and display an error message on the...

Страница 15: ...eck power wiring Overload breaker trips check wattage of loads If a problem is verified in the dimmer pack contact your Leprecon dealer for service Because of the high voltages present inside of the d...

Страница 16: ...ard specifies the use of 5 pin XLR connectors DMX 512 currently uses 3 pins of the 5 pin connector Pins 4 and 5 are reserved for future use Some manufacturers are using these pins for communications b...

Отзывы: