INTRODUCTION
Relay time of smooth adjustable delay time to switch.
Time relay may be used in any electrical circuit. Maximum load relay may not exceed 40A.
Built-in potentiometer regulatory controls regulating the delay time of switching relay from 0 to 10
seconds.
In a State of rest Compact are the contacts with
30-87a
relay see figure .
A
.. dose voltage 12V on pin
86
(+)
after a fixed time relay is switched and the contacts with
30-87
are compact, see figure
A
..
Relay time with smooth regulated time switching from 0 to 10 seconds.
Time relay may be used in any electrical circuit. Maximum load relay may not exceed 40A.
Built-in potentiometer regulatory controls regulating the delay time of switching relay.
The relay can be used in any electrical circuit, e.g.:
installations automotive,
installations LPG/CNG,
installations of industrial automation,
alarms,
etc.
TECHNICAL DATA
Power Supply
12V ±25%
Operating temperature
-40..90°C
The range of adjustment of time switch
0..10sek
Maximum load of the circuit relay
40A
Tightness class
IP66
ASSEMBLY
1.
Mount the relay in accordance with diagram
A
.
2.
The Example of connecting delay shutting down the fuel pump in vehicles with the LPG/CNG
installation are in the organization
B
..
NOTE!
Mounted vertically down while safeguarding against contact with water
Mount away from strong sources of heat (i.e. the engine block or in the vicinity of the exhaust manifold).
Mounted away from the ignition and high voltage cables