background image

©  Copyright 2016 Leonton Technologies, Co. Ltd.

 

All Rights Reserved

 

This document contains information, which is protected by copyright. Reproduction, adaptation or 
translation without prior permission is prohibited, except as allowed under the copyright laws.

 

 
 
 

Disclaimer

 

Leonton  Technologies,  Co.  Ltd.  provides  this  manual  without  warranty  of  any  kind,  expressed  or 
implied,  including  but  not  limited  to  the  implied  warranties  of  merchantability  and  fitness  for  a 
particular purpose.  Leonton Technologies, Co. Ltd. may make improvements and/or changes to the 
product  and/or  specifications  of  the  product  described  in  this  manual,  without  prior  notice. 
Leonton  Technologies,  Co.  Ltd.  will  not  be  liable  for  any  technical  inaccuracies  or  typographical 
errors found in this guide. Changes are periodically made to the information contained herein and 
will  be  incorporated  into  later  versions  of  the  manual.  The  information  contained  is  subject  to 
change without prior notice.

 

Содержание PT2-0800 Series

Страница 1: ...Leonton PT2 0800 Series PT2 0800 PT2 0800 T User Manual Version 1 0...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...ysical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 5 Cabling 7 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 DIP Switch Settings 9 Mounting Installation 10 DIN R...

Страница 5: ...with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance All Copper por...

Страница 6: ...on If the DC voltage is supplied by an external circuit please use a protection device on the power supply input Supply by UL Listed industrial use power The industrial Ethernet switch s hardware spec...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PT2 0800 series W x H x D is 30mm x 142mm x 99mm Figure 2 1 PT2 0800 Series Physical Dimensions...

Страница 8: ...is shown below in Figure 2 2 Figure 2 2 The Front Panel of PT2 0800 Series Top View Figure 2 3 below shows the top panel of the PT2 0800 series switch that is equipped with one 6 pin removal terminal...

Страница 9: ...Connected to network 100Mbps Flashing Networking is active Off Not connected to network 10 LAN Port Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network PoE...

Страница 10: ...ble 2 2 1000BASE T RJ 45 Pin Assignments Table 2 3 Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2...

Страница 11: ...insert the power wire Step 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 14 Figure 2 14 Power Termina...

Страница 12: ...luding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 W...

Страница 13: ...nd the fault LED will turn on Off Disables the corresponding PORT alarm The relay will form a closed circuit and the fault LED will never turn on B S P On Enables broadcast storm protection B S P Off...

Страница 14: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Страница 15: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Страница 16: ...ottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket...

Страница 17: ...the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power In...

Страница 18: ...assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...