Leonton PT2-0501-M-24 Series Скачать руководство пользователя страница 3

FCC Notice

 

This  equipment  has  been  tested  and found to  comply  with  the  limits  for  a  Class-A  digital device, 
pursuant  to  Part  15  of  the  FCC  rules.  These  limits  are  designed  to  provide  reasonable  protection 
against harmful interference in a residential installation. This equipment generates, uses, and can 
radiate radio frequency energy. It may cause harmful interference to radio communications if the 
equipment  is  not  installed  and  used  in  accordance  with  the  instructions.  However,  there  is  no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by  turning  the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of 
the following measures:

 

 

Reorient or relocate the receiving antenna.

 

 

Increase the separation between the equipment and receiver.

 

 

Connect the equipment into an outlet on a circuit different from that to which the receiver 
is connected.

 

 

Consult the dealer or an experienced radio/TV technician for help.

 

 
 

Caution: Any changes or modifications not expressly approved by the grantee of this device could 
void the user's authority to operate the equipment.

 

 
 

CE Mark Warning

 

This is a Class-A product. In a domestic environment this product may cause radio interference in 
which case the user may be required to take adequate measures.

 

 
 

This document is the current official release manual. Please check our website (www.leonton.com) 
for any updated manual or contact us by e-mail (sales@leonton.com).

 

Содержание PT2-0501-M-24 Series

Страница 1: ...Leonton PT2 0501 M 24 Series PT2 0501 M 24 PT2 0501 M 24 T User Manual Version 1 0 ...

Страница 2: ...ut not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Leonton Technologies Co Ltd will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are period...

Страница 3: ... the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Ca...

Страница 4: ...cription 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 5 Cabling 6 Wiring the Power Inputs 7 Wiring the Fault Alarm Contact 8 Mounting Installation 9 DIN Rail Mounting 9 Wall Mounting 11 Hardware Installation 12 Installation Steps 12 Trouble Shooting 13 ...

Страница 5: ...ng temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Features Interface Performance All Copper ports support auto MDI MDI X function Embedded 4 10 100Tx PSE 30W Port and 1 100Fx SC ST type connector with Multi Single mode Store and forward switching architect...

Страница 6: ...ntion If the DC voltage is supplied by an external circuit please use a protection device on the power supply input Supply by UL Listed industrial use power The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Страница 7: ...3 Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PT2 0501 M 24 series W x H x D is 46mm x 142mm x 99mm Figure 2 1 PT2 0501 M 24 Series Physical Dimensions ...

Страница 8: ...hown below in Figure 2 2 Figure 2 2 The Front Panel of PT2 0501 M 24 Series Top View Figure 2 3 below shows the top panel of the PT2 0501 M 24 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 36VDC Figure 2 3 Top Panel View of PT2 0501 M 24 Series ...

Страница 9: ... is active Off Not connected to network Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network PoE Port 1 4 Green On The port is supplying power to the powered device Off No powered device attached or power supplying fails SC ST Port LINK ACT Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network Table 2 1 LED Indict...

Страница 10: ...al Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3 TP1 3 TP0 4 TP2 7 TP3 4 TP2 4 TP3 5 TP2 8 TP3 5 TP2 5 TP3 6 TP1 2 TP0 6 TP1 6 TP0 7 TP3 4 TP2 7 TP3 7 TP2 8 TP3 5 TP2 8 TP3 8 TP2 Table 2 3 Note and signs represent the polarity of the wires that make up each wire pair Cabling Use the four twisted pair category 5e or the above cab...

Страница 11: ...ontacts on the terminal block connector as shown below in Figure 2 14 Figure 2 14 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 15 Figure 2 15 Power Terminal Block Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG ...

Страница 12: ...cluding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 Wiring the Fault Alarm Contact Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power faul...

Страница 13: ...gure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch Step 2 To remove the DIN Rail bracket do the opposite from Step 1 Step 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of ...

Страница 14: ...pull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Ethernet switch from the rail do the opposite from the above steps ...

Страница 15: ...bottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall Step 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch Below in Figure 3 5...

Страница 16: ... to the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication Step 5 Prepare the twisted pair straight through category 5 cable for Ethernet connection Step 6 Insert one side of...

Страница 17: ...To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power losses or surges at the powe...

Отзывы: