16 

 

Hardware Installation 

Installation Steps 

This section will explain how to install ET5-0802-M series: 8-port industrial managed Ethernet 
switch, with 6*10/100Tx Fast Ethernet, and 2*100Fx SC/ST type connector (Multi/Single 
mode). 

   

Caution:

 This device is intended for use indoor and at altitudes up to 2000 meters.   

   

Caution:

 The device is intended to be installed in an industrial control enclosure and panel. 

 
 

Installation Steps 

Step 1

 

Unpack the industrial Ethernet switch from the original packing box. 

Step 2

 

Check if the DIN-Rail bracket is screwed on the industrial Ethernet switch.   

 

If the DIN-Rail is not screwed on the industrial Ethernet switch, please refer to the 

DIN-Rail Mounting

 section for DIN-Rail installation.   

 

If you want to wall mount the industrial Ethernet switch, please refer to the 

Wall 

Mounting

 section for wall mounting installation. 

Step 3

 

To hang the industrial Ethernet switch on a DIN-Rail or wall, please refer to the 

Mounting Installation

 section. 

Step 4

 

Power on the industrial Ethernet switch and then the power LED light will turn on. 

 

If you need help on how to wire power, please refer to the 

Wiring the Power Inputs

 

section.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 5

 

Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection. 

Step 6

 

Insert one side of the RJ-45 cable into switch’s Ethernet port and on the other side 
into the networking device’s Ethernet port, e.g. switch PC or server. The Ethernet 
port’s (RJ-45) LED on the industrial Ethernet switch will turn on when the cable is 
connected to the networking device.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

Step 7

 

When all connections are set and the LED lights all show normal, the installation is 
complete. 

Содержание ET5-0802-M Series

Страница 1: ...Leonton ET5 0802 M Series ET5 0802 M ET5 0802 M T User Manual...

Страница 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Страница 3: ...the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Страница 4: ...ysical Dimensions 4 Front Panel 5 Top View 5 LED Indicators 6 Ethernet Ports 7 Cabling 8 Wiring the Power Inputs 9 Grounding Note 10 Wiring the Fault Alarm Contact 11 Mounting Installation 12 DIN Rail...

Страница 5: ...temperature of 40 to 75 C this series is designed to meet any needs for industrial automation outdoor application and harsh environments Software Features Network Redundancy STP RSTP MSTP ITU T G 803...

Страница 6: ...10 100Tx Fast Ethernet and 2 100Fx SC ST type connector Multi Single mode Store and forward switching architecture 8K MAC Address Table 1Mbits memory buffer Power Input Redundant power DC 12 48V with...

Страница 7: ...an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within...

Страница 8: ...w shows the physical dimensions of ET5 0802 M series 8 port industrial managed Ethernet switch with 6 10 100Tx Fast Ethernet and 2 100Fx SC ST type connector Multi Single mode W x D x H is 54mm x 99mm...

Страница 9: ...own below in Figure 2 2 Figure 2 2 The Front Panel of ET5 0802 M Series Top View Figure 2 3 below shows the top panel of the ET5 0802 M series switch that is equipped with one 6 pin removal terminal b...

Страница 10: ...n Broken MASTER Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active RING Green On ERPS Ring Network is active and works well Flashing ERPS Ring works abnormally or misconfi...

Страница 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 5 1000BASE T RJ 45...

Страница 12: ...ser LED Beam Cabling Use the four twisted pair category 5e or the above cabling for RJ 45 port connections The cable between the switch and the link partner switch hub workstation etc must be less tha...

Страница 13: ...2 contacts on the terminal block connector as shown below in Figure 2 8 Figure 2 8 Power Terminal Block Step 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figur...

Страница 14: ...romagnetic interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown blow in Figure 2 10 Figure 2 10 Gro...

Страница 15: ...uding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 41 Figure 2 41 Wi...

Страница 16: ...and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch...

Страница 17: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Страница 18: ...the wall mounting brackets on the top and bottom of the industrial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for ti...

Страница 19: ...15 Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions...

Страница 20: ...refer to the Wall Mounting section for wall mounting installation Step 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section Step 4 Power on...

Страница 21: ...l as other cables Be careful when handling them so as to not trip over Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes located in the different faces o...

Страница 22: ...ssist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicatio...

Отзывы: