8.6  Install Easy-Mon X Package by select the operating system of your computer. Then, click 

 

“Select” button and follow instruction on screen.

8.7  When Easy-Mon X is completely installed, Open the “Easy-Mon X Setup”. Then, click “Auto 

 

Detect UPS” button to search for UPS and communication port automatically.

8.8  Once the location of UPS communication port has been found. Open the “Easy-Mon X Spy”   

 

program to monitor power data and operating status of the UPS.

LEN.MAN.UPS.107 Rev.3.00/2012

 

www.leonics.com

 

  

 

Copyright © 2012 Leonics Co., Ltd. All rights reserved.

Содержание VIPER

Страница 1: ...on 1 1 3 Battery safety 2 2 INTRODUCTION 3 2 1 General 3 2 2 Features 3 2 3 Optional 3 2 4 Special Optional 4 3 FRONT AND REAR PANEL 4 3 1 Front panel 4 3 2 Rear panel 5 4 INSTALLATION AND OPERATION 6 4 1 Preparation 6 4 2 Installation 6 5 TROUBLESHOOTING 8 6 BATTERY REPLACEMENT 9 7 STORAGE 10 8 SOFTWARE INSTALLATION 10 ...

Страница 2: ...nstructions and caution markings on the UPS and all connected loads and all sections of this user guide 1 2 2 Install this unit in a temperature and humidity controlled indoor area with adequate air flow and away from chemical particles or flammable substances Avoid installing the unit near radio transmission station heat dissipation equipment and direct sunlight 1 2 3 This unit has ventilation gr...

Страница 3: ...the laser printer from surges This outlet does not supply backup power when power fails Automatic No load shutdown UPS shuts down itself automatically when there is no connected load when power fails in order to save battery power Automatic restart After the utility line turns back to normal UPS will restart itself automatically Automatic UPS and Battery Test When startup the UPS it will start tes...

Страница 4: ...own when power fails and there is no connected loads Total power of all connected loads are lower than 60 Watt This special optional switch is not supplied with the standard product 6 3 2 9 Additional UPS Output option The special optional extra Europe CEE 7 socket which is connected to UPS backup power system These special optional socket is not supplied with standard product INSTALLATION AND OPE...

Страница 5: ...e condition of the internal battery Only connect the UPS to utility line and turn on then leave the UPS connected to utility line for at least 8 hours 8 TROUBLESHOOTING Symptoms Possible causes Solutions Turn on POWER switch LINE indicator extinguished and alarm sounds but UPS oper ates normally AC INPUT power cord is not properly plugged in to the utility line Properly plug in the AC INPUT power ...

Страница 6: ...storage UPS for long period of time be sure that battery is fully charged and it need to be recharged every three months to preserve the condition of the internal battery 7 1 Plug the AC INPUT power cord to utility line 7 2 Turn on the POWER switch and leave the UPS connected to the utility line for at least 8 hours 7 3 Test the UPS by following the section 4 2 8 7 4 Turn off the UPS and disconnec...

Страница 7: ...ely installed Open the Easy Mon X Setup Then click Auto Detect UPS button to search for UPS and communication port automatically 8 8 Once the location of UPS communication port has been found Open the Easy Mon X Spy program to monitor power data and operating status of the UPS LEN MAN UPS 107 Rev 3 00 2012 www leonics com Copyright 2012 Leonics Co Ltd All rights reserved ...

Отзывы: