1

 

LMS-188-4P-SM 

4 POINT DIGITAL MONITOR/ALARM 

OPERATING INSTRUCTIONS 

 

 

 

1360 Elmwood Avenue 

Cranston, RI 02910 

Tel (401) 461-1200  Fax (401) 941-5310 

Toll-free (800) 222-1208    www.leonardvalve.com 

G

LMS

188

4P

SM

 

January

 

5,

 

2018

 

Содержание LMS-188-4P-BMS-SM

Страница 1: ...Page 1 LMS 188 4P SM 4 POINT DIGITAL MONITOR ALARM OPERATING INSTRUCTIONS 1360 Elmwood Avenue Cranston RI 02910 Tel 401 461 1200 Fax 401 941 5310 Toll free 800 222 1208 www leonardvalve com G LMS 188...

Страница 2: ...Power down Sequence 4 Runtime Display 4 Alarm Conditions 5 Temperature Alarms 5 Low High Alarm Limits 5 Min Max Readings 5 LMS Email Notification Feature 6 LMS Overview 11 RDU Option Installation Inst...

Страница 3: ...Multi Probe Alarm System are highly accurate temperature sensors The sensor may be put in water or other mild aqueous solutions from 100 C to 100 C NOTE Avoid submerging the probe in solvents or harsh...

Страница 4: ...rap pipe and sensor with insulation supplied by others Strap the insulation to the pipe Power up Shows LMS startup screen NO BATTERY Power Down Install Battery The unit will run without a backup batte...

Страница 5: ...pping the appropriate Relay s Units with individual channel relays have individual Relay Delay times Units with a single relay have one Relay Delay time that applies to any alarm condition Limit Param...

Страница 6: ...number of IP 168 IP3 IP 3 Third number of IP 0 IP4 IP 4 Fourth number of IP 141 NetworkCode PassCode 5 digit PassCode for Setup web page access 30000 to 30000 22718 Depending on the Network being util...

Страница 7: ...directions 1 Get to the Network and Sharing Center section either through Control Panel or the internet connection icon on your taskbar 2 Click on Local Area Connection to bring up the status page 3 C...

Страница 8: ...LMS Operating Manual Page 8...

Страница 9: ...is utilized See Network administrator for DNS Server SMTP information If these parameters are unavailable use 8 8 8 8 for DNS Server smtp 1and1 com for SMTP Server t140 hampshirecontrols com for SMTP...

Страница 10: ...IP address to access the unit After reviewing main web page add setup html to the IP to access the Setup Info Name setupadmin unchangable case sensitive Passcode 22718 Enter your Subnet Mask Gateway D...

Страница 11: ...RelayDelay 2RelayDelay Mute Special Group SETUP 1 Offset 2 Offset channels 1 Define 0 tenthC 1 wholeC 2 tenthF 3 wholeF 4 wholeRH 2 Define Relay Def 0 single unit relay 1 individual channel relays Doo...

Страница 12: ...while still providing the degree of safety required III Installation 1 Remove the plastic case cover by removing the 2 Phillips screws from the back Apply light pressure on the face plate the cover a...

Страница 13: ...hat an alarm condition has persisted for the set time and has been transmitted to the monitoring device this LED will continue to flash even if the alarm condition has corrected itself Pressing RESET...

Страница 14: ...uires a dedicated 110 VAC outlet to plug into See wiring diagram below for reference Do Not Energize SCO LMS 188 4P SM or solenoid valve until wiring is complete Solenoid valve and associated power su...

Страница 15: ...rm is active the relay on the LMS 188 4P SM will switch to N C and the solenoid will shut down Solenoid valve and associated power supply are to be provided by others Installation Solenoid power suppl...