background image

Acquaer Ltd. 

 

 H-

4900, Fehérgyarmat, Szatmári út 11.

 

 

Guarantee terms 

Please carefully retain the guarantee card completed by the seller, or the proof 
of purchase. 

 

Pre-conditions for the 24-month guarantee entitlement: 

- Deployment of the device solely for private use.  

The  guarantee  is  reduced  to  12  months  in  the  commercial  sector  or  leasing 
business.  

-  Proper  handling  and  observance  of  all  information  given  in  the  operating  manual, 
which forms part of our guarantee terms. 
- Observance of the prescribed maintenance intervals  
- No unauthorized alteration of the design.  
- Presentation of the completed guarantee card and/or proof of purchase.  
 

Any  guarantee  claim  shall  be  immediately  void  in  the  event  of  unauthorized 
repairs.  Faults and defects, which can be traced to material  or manufacturing 
faults will be rectified exclusively by our contracted workshops (the seller has 
the right to remedy a defect) in your vicinity or by the manufacturer if the latter 
is closer. Any claims going beyond the provision of a guarantee are ruled out. 
Any  transport  damage  should  be  reported  not  to  us  but  to  the  shipper  in 
question  since,  otherwise,  any  compensation  claims  the  shipper  would  be 
voided. 
 
Information concerning the packaging materials  

The used packaging materials must be thrown into the relevant waste collector. 

In  case  of  the  need  of  any  parts,  questions  or  service  instructions  please 
contact: 

 

[email protected] 

 

+36 30 508-6563 

 

Acquaer Ltd., 4900 Fehérgyarmat, Szatmári u. 11 certifies CE conformity of the above-
mentioned product  and  that  it  complies  with  the  technical data  specified  in  the data 
plate and the “Operating instructions”.

 

 

You can get detailed information about the CE declarations at: 

www.gamagarden.eu

  

Содержание APm37

Страница 1: ...Acquaer Ltd H 4900 Fehérgyarmat Szatmári út 11 PERIPHERIAL PUMP Instruction Manual APm37 APm75 ...

Страница 2: ...ces as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available Applications It is applicable to household water supply equipment support small air conditioning system pipeline pressurization garden watering vegetable greenhouse watering fish breeding and poultry raising etc Transfer clean water and other n...

Страница 3: ...er 0 25 2 2kW Max Suction 8m Insulation class IPX4 Protection class F Max ambient temperature 40 Max liquid temperature 60 Type APm37 APm75 Power 370 W 0 5 HP 750 W 1 0 HP Inlet outlet diameter 1 1 1 1 Qmax 2 4 m3 h 3 0 m3 h Hmax 35 m 70 m Max Suction 8 m 8 m Gross weight 5 5 kg 10 5 kg Package 283x158x171mm 335x190x210mm ...

Страница 4: ...ure normal and safety operation of the electric pump read the manual carefully before use The electric pump should have reliable grounding to prevent short circuit for safety leakage protection switch should be equipped and be careful not to wet the power plug socket should be connected in damp proof area Do not touch the electric pump while working do not wash swim near working area or let livest...

Страница 5: ...alves in both sides of the bump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded Do not transfer any inflammable explosive or gasified liquids that beyond the stipulation Ensure the pump will not be accidently turned on while installing and maintaining if not used for a long time cut off the power first and then turn off valves in inlet and outlet...

Страница 6: ...ture POS Part POS Part 1 Pump body 10 Fan 2 Impeller 11 End plate 3 Mechanical seal 12 Cable holder 4 Support 13 Cord clip 5 Water proof gland 14 Capacitor 6 Bearing 15 Capacitor box 7 Rotor 16 Terminal board 8 Spring washer 17 Stator 9 Fan cover 18 Filling plug ...

Страница 7: ...ards Install pipelines properly as stipulated in the manual and meanwhile conduct frost protection measures for the pipeline For the installation the inlet pipe should be as short as possible with the least turnings The pump should be installed in ventilated and dry environment It could be installed outside provided having proper covering to prevent rain and wind For pipeline use valves should be ...

Страница 8: ...st in accordance with that of the water inlet to avoid too much water loss which will influence outlet performance 5 Pay attention to drop of water level while using the foot valve should not be above the water surface B1 6 In case the inlet pipe is longer than 10m or its lifting height exceeds 4m the pipe diameter should exceed diameter of water inlet of the pump 7 Ensure the pumped will not be a...

Страница 9: ...ith power supply In case the working area of the electric pump is too far from the power supply power transmission lines should be of a heavier gauge otherwise the electric pump cannot work normally because the voltage drop is too dramatic A rubber extension cable shall be applied for the electric pump in case of outdoor use Check rotation of the motor three phase motor Check whether operation of ...

Страница 10: ... acquire lower closing pressure o In case the pump is often enabled when the water tap is turned off sometimes it is turned on and sometimes it is turned off check whether pipeline and the bottom valve have leakages and pressure vessel pressure is normal eliminate timely if any o In case the pressure switch is alternately turned on and turned off frequent start after turning on the water tap incre...

Страница 11: ...e Attention In case no water is discharged after being started for more than 5 minutes with water filled turn off the electric pump re fill water or check whether the inlet pipeline has leakages In case of any frost and ice damages please open the drain plug to empty water in the pump chamber When start up the pump again open the drain plug fill water and tighten it and then the pump is usable In ...

Страница 12: ...ir Impeller is jammed Turn rotating shaft of the fan blade terminal with screw driver to let it rotate flexibly or demount the pump body to clear sundries Stator winding is damaged Replace winding coils sendtothe maintenance point for repair The motor is in operation but no water is discharged Incorrect direction of pump rotation Invert two phase wirings of the motor three phase motor The pump is ...

Страница 13: ...lter screen or pump chamber is blocked by foreign materials Clean pipeline foot valve or pump chamber clear sundries Motor works intermittently or the stator winding is burned out The impeller is jammed or under overload operationfora longtime Clear sundries in the pump chamber operate the pump under the rated flow as much as possible Incorrect grounding broken cable or the electric pump is hit by...

Страница 14: ... to material or manufacturing faults will be rectified exclusively by our contracted workshops the seller has the right to remedy a defect in your vicinity or by the manufacturer if the latter is closer Any claims going beyond the provision of a guarantee are ruled out Any transport damage should be reported not to us but to the shipper in question since otherwise any compensation claims the shipp...

Отзывы: