Commissioning and operation
Before switching on
6
l
26
BA 13.0008 − EN 2.1
6
Commissioning
(
Stop!
ƒ
Ensure that the drives are disconnected from the power supply when
working on them!
ƒ
The drive must only be commissioned by qualified personnel!
ƒ
Do not use the drive in rooms exposed to explosion danger!
ƒ
Danger of fire! Do not use flammable detergents or solvents to clean the
drive.
ƒ
Avoid overheating! Deposits and dirt on the drives impede the necessary
heat dissipation and must be removed frequently.
Ensure that no foreign particles ingress into the motor!
6.1
Before switching on
ƒ
Before commissioning
ƒ
Before commissioning after a longer standstill
ƒ
Before commissioning after repair and maintenance of the motor
(
Stop!
Commission the drive system according to the Operating Instructions for the
controller.
Check:
ƒ
Are the mechanical and electrical mountings and fixings o.k.?
ƒ
Are the electrical connections o.k.?
ƒ
Is the cooling air circulation o.k.?
ƒ
Is the protection against overheating (temperature monitoring evaluation) o.k.?
ƒ
Is the motor connected correctly?
ƒ
Does the parameter setting correspond to the motor (see Operating Instructions for
the controller)?