Страница 1: ...Servo motors MQA asynchronous servo motor Mounting and switch on instructions EN...

Страница 2: ......

Страница 3: ...Mounting 15 Electrical installation 16 Important notes 16 Preparation 16 Motor connection 17 Connection via terminal box 17 Connection via ICN connector 19 Commissioning 24 Important notes 24 Before...

Страница 4: ...her with the complete documentation of the product For safety rated attachments observe the enclosed operating instructions of the manufacturer The document includes safety instructions which must be...

Страница 5: ...er documentation with additional information Example EDKxxx see documentation EDKxxx Layout of the safety instructions DANGER Indicates an extremely hazardous situation Failure to comply with this ins...

Страница 6: ...take responsibility for the suitability of the process and circuit proposals All work with and on the product may only be carried out by qualified personnel IEC 60364 and CENELEC HD 384 define the qua...

Страница 7: ...e drive components e g capacitive caused by inverter supply Careful earthing in the marked positions of the components must be carried out There is a risk of burns from hot surfaces Provide protection...

Страница 8: ...power HP 5 10 Continuous standstill torque 5 11 Power factor cos 8 Brake data Type supply voltage electrical power consumption braking torque 9 Feedback 10 Production data 10 2 Material number 10 3 S...

Страница 9: ...at AM32 5V E EQI SinCos absolute value encoder multi turn EnDat AM2048 5V E EQN Resolver RS0 Safety resolver RV03 RV0 SinCos safety incremental encoder single turn IG1024 5V V3 S1S SinCos incremental...

Страница 10: ...phase AC motors 1 Number of pole pairs for resolvers 2 3 4 Number of bits steps or increments per revolution 20 32 128 512 1024 2048 Supply voltage 5 V 8 V 15 V 24 V Interface or signal level Standar...

Страница 11: ...ents and connections on the product Their position size and appearance may vary Brake Motor connection Feedback Temperature monitoring Output flange Output shaft Motor connection Power Brake Cooling F...

Страница 12: ...olts or support plates Do not damage any components during transport Avoid electrostatic discharges on electronic components and contacts Avoid impacts Check the carrying capacity of the hoists and lo...

Страница 13: ...sible in the manufacturer s packaging In dry low vibration environment without aggressive atmosphere Protect against dust and impacts Observe the climatic conditions according to the technical data 4E...

Страница 14: ...shaft only by using the centering thread Align the output shaft and transmission elements exactly to avoid tensions Mount belt pulleys sprockets or gear wheels as close as possible to the shaft shoul...

Страница 15: ...distortion Compensate minor inaccuracies by suitable flexible couplings Fastening Use screws with a minimum property class of 8 8 Observe prescribed tightening torques Secure against unintended loose...

Страница 16: ...e system or machine is responsible for adherence to the limits required in connection with EMC legislation Operation on an external inverter A max pulse voltage amplitude of Upk 1560 V at the motor te...

Страница 17: ...irmly tightened The terminal box has to be free of foreign bodies dirt and humidity All unused cable entries and the terminal box itself must be sealed so that they are dust tight and waterproof The s...

Страница 18: ...terminal Threaded bolt Stripping length mm 18 20 18 Threaded bolt M12 Tightening torque Nm 3 2 15 5 Terminal box power Contact Name Meaning U1 L1 Motor winding phase V1 L2 W1 L3 PE PE PE conductor Ter...

Страница 19: ...the connections 1 3 2 Position Meaning 1 Power connection Brake connection PE connection 2 Feedback connection Connection of temperature monitoring 3 Blower connection Electrical installation Motor co...

Страница 20: ...ent 8 pole 1 2 W U V ICN M40 8 pole Contact Name Meaning BD1 Holding brake BD2 Holding brake PE PE PE conductor U U Power phase U V V Power phase V W W Power phase W 1 Not assigned 2 Not assigned Elec...

Страница 21: ...ed 10 Schirm Encoder housing shield 11 Temperature monitoring PT1000 12 Temperature monitoring PT1000 ICN M23 connector assignment Incremental and SinCos absolute value encoder Hiperface 1 2 3 4 5 6 7...

Страница 22: ...ot assigned 4 0 V Sensor 0 V sensor 5 PT1000 KTY temperature sensor 6 PT1000 KTY temperature sensor 7 UB Supply 8 Takt EnDat interface cycle 9 Takt Inverse EnDat interface cycle 10 GND Mass 11 Schirm...

Страница 23: ...class due to incorrect mounting Malfunctions may occur ICN connector with screwed connection Do not remove O ring ICN connector with bayonet lock remove O ring and dispose of it 1 1 When connecting th...

Страница 24: ...ence of the motor connection correct Is the contact of good electrical conductivity if a PE connection on the motor housing is used After a long period of downtime or after overhauling the motor check...

Страница 25: ...ly If equipped with blower clean the air inlets regularly Brake The brakes are not accessible from the outside Maintenance work of the brake must only be carried out by Lenze Service personnel Feedbac...

Страница 26: ...operation of the drive system First check the possible causes of malfunction according to the 4Diagnostics and fault elimination 27 If the fault cannot be remedied using one of the measures listed pl...

Страница 27: ...ing flange during project planning Motor suddenly stops and does not restart Overload monitoring of the inverter is activated Check inverter settings Reduce load caused by longer acceleration times In...

Страница 28: ...USA UL Asia Country Conformity approval Product representation China EFUP mark Protection of persons and device protection Protection class EN IEC 60529 EN IEC 60034 5 IP23S Temperature class EN IEC 6...

Страница 29: ...altitude 0 1000 m amsl Without current derating 1000 4000 m amsl Reduce power by 5 1000 m Air humidity Average relative humidity 85 Without condensation Vibration resistance Operation EN 60721 3 3 19...

Страница 30: ...Imax A 188 106 344 201 182 110 Rated voltage Vrated V 360 360 360 360 360 360 Rated frequency frated Hz 100 50 100 58 50 28 Moment of inertia J kgcm 171 171 487 487 487 487 Efficiency 0 900 0 800 0 90...

Страница 31: ...5 178 Rated voltage Vrated V 340 360 360 360 Rated frequency frated Hz 76 42 36 20 Moment of inertia J kgcm 1340 1340 1340 1340 Efficiency 0 920 0 820 0 870 0 810 Stator terminal resistance RUV 20 C 0...