ICN-M23 connector assignment
SinCos absolute value encoder with EnDat interface
1
2
3
4
5
6
7
9
10
11
12
13
14
15
16
17
8
Code 0°
ICN M23 SinCos absolute value encoder with EnDat
Contact
Name
Meaning
1
UP Sensor
Up Sensor
2
Not assigned
3
Not assigned
4
0 V Sensor
0 V sensor
5
+
PT1000/KTY temperature sensor
6
-
PT1000/KTY temperature sensor
7
+UB
8
Takt
EnDat interface cycle
9
Takt-
Inverse EnDat interface cycle
10
GND
Mass
11
Schirm
Encoder housing shield
12
B
Track B
13
B-
Track B inverse/-SIN
14
Daten
EnDat interface data
15
A
Track A
16
A-
Track A inverse / - COS
17
Daten-
Data inverse EnDat interface
Blower
Pin assignment ICN-M17
1
4
2
5
6
3
+
ICN M17 for blowers 1-ph
Contact
Name
Meaning
PE
PE
PE conductor
1
U1
Fan
2
U2
Fan
3
Not assigned
4
Not assigned
5
Not assigned
6
Not assigned
Electrical installation
Motor connection
Connection via ICN connector
32